Seismic Performance Evaluation of Building-Damper System under Near-Fault Earthquake

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of Seismic Performance and Effectiveness of Multiple Slim-Type Damper System for Seismic Response Control of Building Structures

This paper presents the evaluation of seismic performance and cost-effectiveness of a multiple slim-type damper system developed for the vibration control of earthquake excited buildings. The multiple slim-type damper (MSD) that consists of several small slim-type dampers and linkage units can control damping capacity easily by changing the number of small dampers. To evaluate the performance o...

متن کامل

Seismic Mitigation of Building Frames using Magnetorheological Damper (TECHNICAL NOTE)

The present study focusses on the damping force control of shear mode magnetorheological (MR) damper for seismic mitigations. Therefore, the semi-active MR damper which can control the vibration is analyzed both experimentally and numerically. Carbonyl iron is used as the magnetic particle and Castrol Magnetec oil as carrier fluid throughout the study. MR damper is designed and fabricated, and ...

متن کامل

Performance Evaluation of Curved-TADAS Damper on Seismic Response of Moment Resisting Steel Frame

In this study, the performance of triangular added damping and stiffness (TADAS) dampers combined with curved dampers (Curved-TADAS damper) is evaluated in moment resisting steel frame (MRSF). These dampers are passive and install in the beam-column connection region. Variable parameters of this study involve the width of curved damper (50, 75 and 100 mm), the thickness of TADAS damper (5 and 1...

متن کامل

Seismic Fault Rheology and Earthquake Dynamics

As preparation for this Dahlem Workshop on The Dynamics of Fault Zones, specifically on the subtopic “Rheology of Fault Rocks and Their Surroundings,” we addressed critical research issues for understanding the seismic response of fault zones in terms of the constitutive response of fault materials. This requires new concepts and a host of new observations and experiments to document material r...

متن کامل

Seismic Response Reduction of a Building Using Top-Story Isolation System with MR Damper

In this study, the adaptability of a semi-active top-story isolation system with an MR damper for reduction of seismic responses of tall buildings has been investigated. To this end, a 20-story building structure was selected as an example. Low damping elastomeric bearings and an MR damper were used to compose a smart top-story isolation system. Artificial earthquakes generated based on design ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Shock and Vibration

سال: 2020

ISSN: 1070-9622,1875-9203

DOI: 10.1155/2020/2763709