Seismic Isolation for Buildings. Application of Rubber Bearing to Base-Isolated House.
نویسندگان
چکیده
منابع مشابه
Influence of Seismic Pounding on RC Buildings with and without Base Isolation System Subject to Near-Fault Ground Motions
Building pounding occurs between two adjacent buildings with small gap or without sufficient separation distance. It leads to damage buildings during earthquake due to impact. Many researchers have investigated building pounding based on impact force reduction and energy dissipation increase, when two buildings collide with each other. In numerical investigations, using specific link element, i...
متن کاملAdaptive fuzzy control for earthquake-excited buildings with lead rubber bearing isolation
This study examines the feasibility of applying adaptive fuzzy sliding mode control (AFSMC) strategies to reduce the dynamic responses of buildings constructed using a lead rubber bearing (LRB) isolation hybrid protective system. Recently developed control devices for civil engineering structures, including hybrid systems and semi-active systems, have been found to have inherent nonlinear prope...
متن کاملDesign of Base Isolation System for Buildings
The concept and theory of base isolation system are widely accepted at the present. To accomplish the predicted behaviours of the base-isolated buildings, the design for base isolation system is regarded as the dominant factor of the success of isolated buildings. Although the base isolation design can be fulfilled using Uniform Building Code 1997, conceptual design is yet necessarily analyzing...
متن کاملFuzzy control of piezoelectric friction dampers for seismic protection of smart base isolated buildings
This study proposes two fuzzy logic controllers (FLCs) for operating control force of piezoelectric friction dampers used for seismic protection of base-isolated buildings against various types of earthquake excitations. The first controller employs a hierarchic control strategy in which a higher-level supervisory controller operates a single sub-level FLC by modifying its input normalization f...
متن کاملSimplified Method for the Seismic Design of Low-Rise, Shear Wall Base- Isolated Buildings
A simplified method for the seismic design of low-rise, base-isolated shear wall structures is proposed in MOC-2012. This simplified method is basically a hybrid method, where the design of the isolation system is a simpler version for the static method available in US guidelines for the design of base-isolated structures and the design of the superstructure essentially is an improved version o...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: NIPPON GOMU KYOKAISHI
سال: 1997
ISSN: 1884-0442,0029-022X
DOI: 10.2324/gomu.70.462