Seismic control of vertically and horizontally irregular steel high-rise buildings by tuned mass dampers including SSI

نویسندگان

چکیده

Abstract The architectural requirements imposed on the structural design of buildings sometimes necessitate vertical and horizontal irregularities with their possibly dangerous effects when these structures are subjected to earthquakes. One greatest challenges in engineering is a steel high-rise building (HRB) irregularities. In this research, two irregular (HRBs) were seismically analyzed as 3D models considering soil–structure interaction (SSI) tuned mass damper (TMD) systems used mitigate seismic response under different studied HRBs vertically (step-pyramid-shaped) HRB, both horizontally (L-shaped in-plan, stadium-shaped) HRB. SSI provides actual tall earthquake, mitigation schemes using TMDs suggested arrangements top plan along elevation achieve control structures. present study has shown that best efficiency effect earthquakes obtained by implementing at corners HRB also floor levels upper half-height

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Tuned Mass Dampers for Earthquake Vibrations of High-rise Buildings using Bee Colony Optimization Technique

This paper investigates the application of Artificial Bee Colony (ABC) method for the optimization of Tuned Mass Dampers (TMDs) employed for high-rise structures including Soil Structure Interaction (SSI). The model is a 40-story building, and Newmark method is utilized for the structure response to Bam earthquake data. The objective is to decrease both maximum displacement and accelerati...

متن کامل

OPTIMIZED TUNED LIQUID COLUMN DAMPERS FOR EARTHQUAKE OSCILLATIONS OF HIGH-RISE STRUCTURES INCLUDING SOIL EFFECTS

This paper investigates the optimized parameters for the tuned liquid column dampers to decrease the earthquake vibrations of high-rise buildings. Considering soil effects, the soilstructure interaction (SSI) is involved in this model. The Tuned Liquid Column Damper (TLCD) is also utilized on the roof of the building. Since the TLCD is a nonlinear device, the time domain analysis based on nonli...

متن کامل

«research note» vibration control of high-rise buildings with tuned mass dampers (case study: tehran international tower)

abstract: appealing to the principle of vertical residence and stemming the horizontal expansion of the city, the tehran milad tower is being built on 35000 sm3 site with the total area of 220000 sm3. with a height of over 170m, this 56-story concrete building is in the final stages of construction and would be the highest residential building of iran. since tehran is located in a high-risk ear...

متن کامل

Semiactive Tuned Mass Dampers

Studies have already demonstrated the successful use of linear semiactive damping devices, such as variable orifice (VO) dampers, for semiactive TMD systems. More recently, nonlinear semiactive damping devices, such as magnetorheological (MR) dampers, have also been shown to be effective for semiactive control of TMDs. Though semiactive dampers differ widely, with responses ranging from linear ...

متن کامل

Seismic Vibration Control of 3D Steel Frames with Irregular Plans Using Eccentrically Placed MR Dampers

Abstract: There has been a significant increase in attention toward designing smart structures and vibration control of structures in recent decades, and numerous methods and algorithms have been developed and experimentally investigated. However, the majority of these studies used the shear frame models to represent structures. Since the simplified models do not reflect the realistic behavior ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Asian Journal of Civil Engineering

سال: 2023

ISSN: ['2522-011X', '1563-0854']

DOI: https://doi.org/10.1007/s42107-023-00890-0