Seismic Control of Continuous Bridges Using Variable Radius Friction Pendulum Systems and Viscous Fluid Dampers
نویسندگان
چکیده
منابع مشابه
Seismic Response Study of Asymmetric Systems with Linear and Nonlinear Fluid Viscous Dampers
This investigation is concerned with application of nonlinear fluid viscous dampers for asymmetric-plan systems. For this purpose, the behavior of nonlinear fluid viscous dampers is summarized first followed by the effects of damper nonlinearity on seismic response of asymmetric systems. It is shown that the peak force in nonlinear damper tends to be smaller compared to linear damper. However, ...
متن کاملStructural Control Based on Semi-active Variable Friction Dampers
This paper discusses a methodology of semi-active structural control using a variable friction damper. The presented algorithm is quite simple and straightforward, in which only the slip level of the friction damper is controlled in response to the interstory response velocity of the damperinstalled story so as to maintain the target constant ductility factor. In conducting control there is adv...
متن کاملAdaptive control of base-isolated structures against near-field earthquakes using variable friction dampers
This paper investigates the effectiveness of two adaptive control strategies for modulating control force of variable friction dampers (VFDs) that are employed as semi-active devices in combination with laminated rubber bearings for seismic protection of buildings. The first controller developed in this study is an adaptive fuzzy neural controller (AFNC). It consists of a direct fuzzy controlle...
متن کاملRe-centering variable friction device for seismic control of structures
This paper investigates the seismic response control of a nonlinear benchmark building with a new re-centering variable friction device (RVFD). The RVFD consists of three parts: (i) a friction generation unit, (ii) a piezoelectric actuator, and (iii) shape memory alloy wires. The friction unit and piezoelectric actuator compose the first subcomponent of the hybrid device that is a variable fric...
متن کاملFuzzy control of piezoelectric friction dampers for seismic protection of smart base isolated buildings
This study proposes two fuzzy logic controllers (FLCs) for operating control force of piezoelectric friction dampers used for seismic protection of base-isolated buildings against various types of earthquake excitations. The first controller employs a hierarchic control strategy in which a higher-level supervisory controller operates a single sub-level FLC by modifying its input normalization f...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: The International Journal of Acoustics and Vibration
سال: 2015
ISSN: 2415-1408
DOI: 10.20855/ijav.2015.20.1365