Seismic behaviour of post-tensioned concrete shear wall: a review
نویسندگان
چکیده
منابع مشابه
Horizontal Post - Tensioned Connections for I ' Recast Concrete Load - Bearing Shear Wall Panels
Precast load-bearing shear wall panels are used extensively for high-rise construction because of the ease and speed of assembly, and the high quality of the precast panels. The connections between panels are extremely important since they affect both the speed of erection and the overall integrity of the structure. This paper presents the results of a research program conducted to investigate ...
متن کاملSeismic Performance of Steel Plate-Reinforced Concrete Composite Shear Wall
In tall buildings the reinforced concrete (RC) shear wall is one of the predominant structural components used to resist lateral loads induced by earthquakes around the world. Previous research demonstrated that shear walls displayed a sudden loss in lateral capacity due to the wall corner and web crushing in the plastic zone. In addition, it was found that large shear distortions in shear wall...
متن کاملSeismic Design Considerations for Precast Concrete Shear Wall Connections
The performance of precast shear wall panel structures subjected to earthquakes relies on the behaviour and integrity of the connections between the panels. The current lack of knowledge on the seismic behaviour of precast wall connections limits the use of such systems in earthquake areas. This paper presents results of an extensive experimental program undertaken at the University of Manitoba...
متن کاملConcrete Shear Wall Construction
Buildings with cast-in-situ reinforced concrete shear walls are widespread in many earthquake-prone countries and regions, such as Canada, Chile, Romania, Turkey, Colombia, the republics of the former Soviet Union, etc. This type of construction has been practiced since the 960s in urban regions for mediumto high-rise buildings (4 to 35 stories high). Shear wall buildings are usually regular in...
متن کاملUnbonded Post Tensioned Concrete in Fire: A Review of Data from Furnace Tests and Real Fires
The fire-safe design of concrete structures which incorporate post-tensioned prestressing tendons has recently been the subject of debate within the structural engineering community, particularly when unbonded post-tensioned (UPT) prestressing tendons are used. Despite several studies aimed at furthering our understanding of the response of UPT concrete structures in fire, many aspects of their...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Sustainability, Agri, Food and Environmental Research
سال: 2021
ISSN: 0719-3726
DOI: 10.7770/safer-v10n1-art2515