Analysis of Carbon Fiber Sheet Retrofitted Rc Bridge Columns
Experimental studies were conducted by some researchers to investigate the cyclic performance of CFSretrofitted columns; however there is a need to develop analytical methods which can simulate its hysteretic response. This study presents an analysis of the hysteretic behavior of CFS-retrofitted reinforced concrete circular columns. Fiber element analysis was conducted based on cyclic constitut...
متن کاملApplication of Near Surface Mounted (NSM) technique for Seismic Retrofitting of Heritage Buildings
The high vulnerability of the cultural buildings due to seismic actions urged researchers to retrofit them using reversible and compatible techniques. The application of fiber reinforced polymer (FRP) for enhancing the structural behavior of masonry buildings, under seismic actions, has been studied by many researchers. The near-surface mounting (NSM) technique is a relatively new retrofitting ...
متن کاملSeismic Behavior of Substandard RC Columns Retrofitted with Embedded Aramid Fiber Reinforced Polymer (AFRP) Reinforcement
Many existing reinforced concrete structures were constructed with substandard characteristics. Low quality concrete, poor transverse reinforcement details and insufficient flexural strength are among the most common deficiencies. While substandard structures are in need of retrofitting, particularly in seismic areas, problems such as high costs and disturbance to occupants are major obstacles ...
متن کاملSeismic assessment of bridge structures isolated by a shape memory alloy/rubber-based isolation system
This paper explores the effectiveness of shape memory alloy (SMA)/rubber-based isolation systems for seismic protection of bridges against near-field earthquakes by performing a sensitivity analysis. The isolation system considered in this study consists of a laminated rubber bearing, which provides lateral flexibility while supplying high vertical load-carrying capacity and an auxiliary device...
متن کاملStrengthening of Rc Structures with near Surface Mounted Frp Rods
Disclaimer The contents of this report reflect the views of the author(s), who are responsible for the facts and the accuracy of information presented herein. This document i s disseminated under the sponsorship of the Center for Infrastructure Engineering Studies (CIES), University of Missouri-Rolla, in the interest of information exchange. CIES assumes no liability for the contents or use the...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Materials
سال: 2020
ISSN: 1996-1944
DOI: 10.3390/ma13071701