Seismic and Wind Analysis of RC Structures with Base Isolator and Fixed Base
نویسندگان
چکیده
منابع مشابه
Behaviour of Base-Isolated Structures with High Initial Isolator Stiffness
Analytical seismic response of multi-story building supported on base isolation system is investigated under real earthquake motion. The superstructure is idealized as a shear type flexible building with lateral degree-of-freedom at each floor. The force-deformation behaviour of the isolation system is modelled by the bi-linear behaviour which can be effectively used to model all isolation syst...
متن کاملInfluence of Seismic Pounding on RC Buildings with and without Base Isolation System Subject to Near-Fault Ground Motions
Building pounding occurs between two adjacent buildings with small gap or without sufficient separation distance. It leads to damage buildings during earthquake due to impact. Many researchers have investigated building pounding based on impact force reduction and energy dissipation increase, when two buildings collide with each other. In numerical investigations, using specific link element, i...
متن کاملEarthquake Analysis of Base Isolated Structures Including Soil-Structure Interaction
A frequency domain dynamic analysis is needed to obtain the response of structures constructed on a system of base isolators on flexible soil when subjected to earthquake ground motion. In such systems, the lateral stiffness of the base isolators is so small, compared to the structural stiffness, that in an earthquake attack the fundamental vibration mode dominates the response. With this in mi...
متن کاملEarthquake Analysis of Base Isolated Structures Including Soil-Structure Interaction
A frequency domain dynamic analysis is needed to obtain the response of structures constructed on a system of base isolators on flexible soil when subjected to earthquake ground motion. In such systems, the lateral stiffness of the base isolators is so small, compared to the structural stiffness, that in an earthquake attack the fundamental vibration mode dominates the response. With this in mi...
متن کاملPillow-Shape Base Isolation System and Its Seismic Behavior
In this paper a new isolating system is introduced for short to mid-rise buildings. In comparison to conventional systems such as LRB and HRB, the proposed system has the advantage of no need to cutting edge technology and has low manufacturing cost. This system is made up of two orthogonal pairs of pillow-shaped rollers that are located between flat bed and plates. By using this system in two ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: International Journal for Research in Applied Science and Engineering Technology
سال: 2021
ISSN: 2321-9653
DOI: 10.22214/ijraset.2021.34504