Seismic Analysis of Regular Tall Buildings with Shear Walls and without Shear Walls at Different Locations
نویسندگان
چکیده
منابع مشابه
Seismic Evaluation with Shear Walls and Braces for Buildings
Abstract—R.C.C. buildings with dual structural system consisting of shear walls (or braces) and moment resisting frames have been widely used to resist lateral forces during earthquakes. The dual systems are designed to resist the total design lateral force in proportion to their lateral stiffness. The response of combination of braces and shear walls has not yet been studied. The combination m...
متن کاملPerformance Based Seismic Rehabilitation of Steel Structures with Different Types of Shear Walls
Seismic rehabilitation provides existing buildings with more resistance to seismic activity, ground motion, or geotechnical failure due to earthquakes. Performance-based rehabilitation is a general concept through which the retrofitting criteria are defined regarding to performance objectives when the structural and nonstructural members are subject to different levels of earthquake hazards. In...
متن کاملReliability-based Seismic Assessment of Asymetric Multi-storey Buildings with Rc Shear Walls
The performance of buildings subjected to earthquake loads has shown that asymmetric structures are caused more extensive damages in comparison with symmetric structures. Hence, the seismic performance of asymmetric structures should be assessed due to future random earthquakes. Reliability-based seismic assessment as one of the tools in performance-based earthquake engineering has been introdu...
متن کاملComparison of plasticity and stiffness of steel shear walls with composite steel plate shear wall
The steel shear wall and composite steel plate shear wall is introduced in recent three decade and is considered and is spread rapidly. Composite steel plate shear wall which is made of a layer of thin steel sheet with coating of reinforced concrete in one or both sides of steel palate is considered a third generation of resistance shear walls against lateral loads that in addition to increasin...
متن کاملSeismic capacity rating and reliability assessment of wood shear walls
A modified version of the BRANZ procedure for lateral capacity rating of bracing walls is used to determine the sustainable lateral mass of a 910-mm wide ‘2x4’ wood shear wall. The key modifications involve: (1) the use of a multicriteria system identification method to determine a structural model that simultaneously fits test data from both cyclic testing and pseudo-dynamic testing; and (2) p...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: International Journal for Research in Applied Science and Engineering Technology
سال: 2018
ISSN: 2321-9653
DOI: 10.22214/ijraset.2018.4046