SEISMIC ANALYSIS OF MULTISTOREY BUILDING WITH BARE FRAME, BARE FRAME WITH SLAB ELEMENT AND SOFT STOREY AT DIFFERENT LEVELS OF THE BUILDING FOR SEISIMIC ZONE II
نویسندگان
چکیده
منابع مشابه
Seismic Vulnerability and Parametric Study on a Bare Frame Building in Nepal
The influence of the infill masonry walls in the structural response of reinforced concrete (RC) structures when subjected to earthquakes is not considered in Nepal National Building code and Indian Standard code. Field observations carried out after the 25th April Gorkha earthquake in Nepal reinforce the importance of the infill walls, namely, through the significant increasing of the structur...
متن کاملthe effect of task cognitive complexity and time limit on the performance of the learners with different proficiency levels in second language writing skill
this study investigated the effects of manipulating the cognitive complexity of tasks along +/- few elements and the time limits on l2 learners writing performance. to conduct the study, 60 iranian efl learners with two levels of proficiency, low and high intermediate, were selected and assigned to three groups based on the time devoted to task completion. the participants performed both a simp...
15 صفحه اولthe role of application of dynamic assessment approach in improvement of iranian efl writing performance at different language proficiency levels
the present study sought to investigate the role of dynamic assessment (da) in improvement of iranian efl writing performance at different language proficiency levels. to this end, after conducting the quick placement test, 60 iranian efl learners were assigned to two groups with different language proficiency levels. in both groups each participant wrote two compositions, one before and one af...
Assessment of an RC existing hospital building with special moment frame using fragility curve
In this study, an existing hospital structure has been evaluated with incremental dynamic analysis (IDA). This building is accommodated in Karaj with soil type II. At first, two 2-D frames along X, Y direction are selected. Then, five performance levels are determined according to “Rehabilitation Code for Existing Buildings (Publication No. 360) including Immediate Operational (IO), Limited Dam...
متن کاملComparative Analysis of a Multistorey Building with and
Viscoelastic dampers are considered to be better than most of the passive energy dissipation devices. Researches done on the improvement of its performance for analyzing structures has always been in vogue. The significant change in the response of the structures to make it resistant to earthquake and wind forces is the main idea behind using such devices. A comparative analysis of a G+44 RCC s...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: International Journal of Research in Engineering and Technology
سال: 2016
ISSN: 2321-7308,2319-1163
DOI: 10.15623/ijret.2016.0508052