Screw Insertion, Method and Distal Locking Screw of Femoral Interlocking Nail.
نویسندگان
چکیده
منابع مشابه
Radiation-free Insertion of Distal Interlocking Screw in Tibial and Femur Nailing: A Simple Technique
BACKGROUND Distal interlocking screw insertion in intramedullary nailing of long-bone fracture is a challenging task for orthopedic surgeons. It is difficult particularly when the surgeon is in his learning stage or when image intensifier is not available. We describe a radiation-free technique of distal interlocking screw insertion which is easy and practicable. MATERIALS AND METHODS In this...
متن کاملComparative study of management of distal femoral fractures managed by dynamic condylar screw and distal femoral locking compression plate
Background:Distal femoral fractures are much less common than hip fractures and account for 7% of all femoral fractures. Distal femoral fractures are difficult to treat and ideal treatment of such fractures will include anatomical reduction, rigid fixation of articular surfaces and early mobilization of knee joint. Our study aims to compare the outcome of fifty distal femoral fractures which we...
متن کاملDistal locking in femoral intramedullary nailing system: Is one cross screw sufficient?
Introduction: The indications for intramedullary nail fixation of fractures of the femoral shaft have been greatly expanded by techniques of interlocking nailing. However, distal locking screw fixation remains the most technically demanding and problematic portion of the procedure and maybe responsible for as much as one-half of the exposure of the surgeon’s hands to radiation during the proced...
متن کاملImaging Evaluation of the Safe Region for Distal Locking Screw of Proximal Femoral Nail Anti-Rotation in Patients with Proximal Femoral Fracture
BACKGROUND Proximal femoral nail anti-rotation (PFNA) is a standard femoral intertrochanteric fracture operation. Iatrogenic vascular injury, although uncommon, is a reported complication of PFNA surgery as well as a complication of hip fracture surgery. This study aimed to compare the safety and best use of the distal locking screw in 170 mm PFNA and 240 mm PFNA devices, and to determine the s...
متن کاملThe Effect of Two Distal Interlocking Screw Configuration and Orientation on Intramedullary Nail Stability: A Biomechanical Study
INTRODUCTION: Long bone diaphyseal fractures are a very common injury encountered in orthopedic practice. This type of fracture is often treated using an intramedullary (IM) nail. In this day and age there are many options in regards to the orientation of the distal interlocking screws. The goal of this study was to determine if the distance between two distal locking screws affects the stabili...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Orthopedics & Traumatology
سال: 2002
ISSN: 1349-4333,0037-1033
DOI: 10.5035/nishiseisai.51.381