Scleral fixation of Ahmed glaucoma valve tube tip for adjustment of cornea-touching malposition
نویسندگان
چکیده
منابع مشابه
Surgical Outcomes of Different Ahmed Glaucoma Valve Implantation Methods between Scleral Graft and Scleral Flap
PURPOSE To compare the surgical outcomes of the two different methods used for Ahmed Glaucoma Valve (AGV) implantation between the donor scleral graft method and the partial-thickness scleral flap method. METHODS We retrospectively reviewed medical records of 28 eyes of 26 patients diagnosed as neovascular glaucoma followed by AGV implantation. Based on the surgical method, the included eyes ...
متن کاملAhmed Glaucoma Valve with Adjunctive Amniotic Membrane for Refractory Glaucoma
PURPOSE To evaluate the efficacy and safety of Ahmed Glaucoma Valve (AGV) implantation with adjunctive use of preserved amniotic membrane for surgical management of refractory glaucoma. METHODS Seven patients (5 female subjects) with refractory glaucoma were included in the study. An AGV (model FP7) was implanted in the usual manner and was covered with two layers of cryopreserved human amnio...
متن کاملA case of WAGR syndrome in association with developmental glaucoma requiring bilateral Baerveldt glaucoma implants and subsequent tube repositioning
Glaucoma drainage device implantation is efficacious for the treatment of pediatric glaucoma patients when multiple angle surgeries fail. However, tube touching of the corneal endothelium is one of the major postoperative complications to deal with. A 15-month-old male patient with Wilms' tumor, aniridia, genitourinary anomalies, and mental retardation (WAGR) syndrome was diagnosed with bilater...
متن کاملLong-term success of ahmed glaucoma valve in refractory glaucoma.
AIM To evaluate the long-term results and complications of ahmed glaucoma valve (AGV) implantation in refractory glaucoma. METHODS A retrospective review of 13 patients (13 eyes) with refractory glaucoma who underwent AGV implantation and had a minimum follow-up of 18 months was performed. All patients underwent a complete ophthalmologic examination and intraocular pressure (IOP) measurement ...
متن کاملIntracameral air injection during Ahmed glaucoma valve implantation in neovascular glaucoma for the prevention of tube obstruction with blood clot
RATIONALE Glaucoma drainage implant surgery is a treatment option for the management of neovascular glaucoma. However, tube obstruction by blood clot after Ahmed glaucoma valve (AGV) implantation is an unpredictable clinically challenging situation. PATIENT CONCERNS-DIAGNOSES-INTERVENTIONS We report 4 cases using intracameral air injection for the prevention of the tube obstruction of AGV by ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Eye
سال: 2013
ISSN: 0950-222X,1476-5454
DOI: 10.1038/eye.2013.214