SCC Initiation for X80 Pipeline Steel Under AC Application in High pH Solution

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Stress- Corrosion Crack Initiation of High-strength Pipeline Steel in Near-neutral pH Environments

Stress-corrosion cracking (SCC) tests were conducted in the near-neutral pH standard solution, NS4, and in an actual soil solution, using four-point bending at a high stress ratio and low frequency conditions very similar to those of operational pipelines. Pitting incubation appeared first and then pitting initiated and grew in both solutions although there were many more pits on the specimen t...

متن کامل

EFFECTS OF ANODIC PROTECTION ON SCC BEHAVIOR OF X80 PIPELINE STEEL IN HIGH-pH CARBONATE-BICARBONATE SOLUTION WPŁYW OCHRONY ANODOWEJ NA NAPRĘŻENIOWE PĘKANIE KOROZYJNE STALI TYPU X80 Z ZASTOSOWANIEM NA RUROCIĄGI W ROZTWORZE BUFOROWYM O WYSOKIM pH

The potentiodynamic polarization test and slow strain rate tensile tests of X80 pipeline steel were performed in 0.5M Na2CO3-1M NaHCO3 solution to study the electrochemical and stress corrosion cracking properties. The results of potentiodynamic polarization test show that there is an obvious stable passive region, about from 0v to 0.8V (SCE), indicating that anodic protection is feasible. The ...

متن کامل

stress- corrosion crack initiation of high-strength pipeline steel in near-neutral ph environments

stress-corrosion cracking (scc) tests were conducted in the near-neutral ph standard solution, ns4, and in an actual soil solution, using four-point bending at a high stress ratio and low frequency conditions very similar to those of operational pipelines. pitting incubation appeared first and then pitting initiated and grew in both solutions although there were many more pits on the specimen t...

متن کامل

Effect of Alternating Current on the Cathodic Protection and Interface Structure of X80 Steel

This study employs potential-monitoring techniques, cyclic voltammetry tests, alternating current (AC) voltammetry methods, and surface characterization to investigate the AC corrosion of cathodically protected X80 pipeline steel. In a non-passive neutral solution at pH 7.2, a sufficiently negative potential completely protects steel at an AC current density of 100 A/m². In an alkaline solution...

متن کامل

Effect of Nanosized NbC Precipitates on Hydrogen Diffusion in X80 Pipeline Steel

In this paper, the effects of dispersed 3~10 nm NbC precipitates on hydrogen diffusion in X80 pipeline steel were investigated by means of high resolution transmission electron microscopy (HRTEM), electrochemical hydrogen permeation, and thermal desorption spectroscopy (TDS). The relationship between hydrogen diffusion and temperature was determined for Nb-free X80 and 0.055 wt% Nb X80 steel. T...