Scattered light fluorescence microscopy in three dimensions

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Scattered light fluorescence microscopy in three dimensions.

Recently, we have proposed a method to image fluorescent structures behind turbid layers at diffraction limited resolution using wave-front shaping and the memory effect. However, this was limited to a raster scanning of the wave-front shaped focus to a two dimensional plane. In applications, it can however be of great importance to be able to scan a three dimensional volume. Here we show that ...

متن کامل

Scattered light fluorescence microscopy: imaging through turbid layers.

A major limitation of any type of microscope is the penetration depth in turbid tissue. Here, we demonstrate a fundamentally novel kind of fluorescence microscope that images through optically thick turbid layers. The microscope uses scattered light, rather than light propagating along a straight path, for imaging with subwavelength resolution. Our method uses constructive interference to focus...

متن کامل

Three Dimensional Fluorescence Imaging Using Multiple Light-Sheet Microscopy

We developed a multiple light-sheet microscopy (MLSM) system capable of 3D fluorescence imaging. Employing spatial filter in the excitation arm of a SPIM system, we successfully generated multiple light-sheets. This improves upon the existing SPIM system and is capable of 3D volume imaging by simultaneously illuminating multiple planes in the sample. Theta detection geometry is employed for dat...

متن کامل

Two-photon Fluorescence Light Microscopy

The invention of two-photon fluorescence light microscopy by Denk, Webb and co-workers (Denk et al., 1990) revolutionized three-dimensional (3D) in vivo imaging of cells and tissues. In 1931, the theoretical basis of twophoton excitation was established by Maria GöppertMayer, and this photophysical effect was verified experimentally by Kaiser and Garret in 1963. Two-photon excitation is a fluor...

متن کامل

Three-dimensional holographic fluorescence microscopy.

Most commonly used methods for three-dimensional (3D) fluorescence microscopy make use of sectioning techniques that require that the object be physically scanned in a series of two-dimensional (2D) sections along the z axis. The main drawback in these approaches is the need for these sequential 2D scans. An alternative approach to fluorescence imaging in three dimensions has been developed tha...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Optics Express

سال: 2012

ISSN: 1094-4087

DOI: 10.1364/oe.20.003744