Scanning two-photon continuous flow lithography for synthesis of high-resolution 3D microparticles
نویسندگان
چکیده
منابع مشابه
Synthesis of biomimetic oxygen-carrying compartmentalized microparticles using flow lithography.
We report a microfluidic approach for lithographically photo-patterning compartmentalized microparticles with any 2D-extruded shape, down to the cellular length scale (~10 microns). The prepolymer solution consists of a UV crosslinkable perfluorodecalin-in-water nanoemulsion stabilized by Pluronic(®) F-68. The nanoemulsions are generated using high-pressure homogenization and are osmotically st...
متن کاملTwo-Photon Interferometry for High-Resolution Imaging
We discuss the advantages of using non-classical states of light for two aspects of optical imaging: the creation of microscopic images on photosensitive substrates, which constitutes the foundation for optical lithography, and the imaging of microscopic objects. In both cases, the classical resolution limit given by the Rayleigh criterion is approximately half of the optical wavelength. It has...
متن کاملHigh-speed, two-photon scanning microscope.
We have developed a high-speed two-photon microscope with submicrometer resolution in real time. The imaging speed improvement of this system is obtained by the use of a high-speed polygonal mirror scanner. The maximum achievable scanning rate is 40 micros/line, which is approximately 100 times faster than conventional scanning microscopes. High-resolution fluorescence images were recorded in r...
متن کاملLock release lithography for 3D and composite microparticles.
We present a method called "Lock Release Lithography (LRL)" that utilizes a combination of channel topography, mask design, and pressure-induced channel deformation to form and release particles in a cycled fashion. This technique provides a means for the high-throughput production of particles with complex 3D morphologies and composite particles with spatially configurable chemistries. In this...
متن کاملFrustrated FRET for high-contrast high-resolution two-photon imaging.
Two-photon fluorescence microscopy has become increasingly popular in biomedical research as it allows high-resolution imaging of thick biological specimen with superior contrast and penetration than confocal microscopy. However, two-photon microscopy still faces two fundamental limitations: 1) image-contrast deterioration with imaging depth due to out-of-focus background and 2) diffraction-lim...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Optics Express
سال: 2018
ISSN: 1094-4087
DOI: 10.1364/oe.26.013543