Scanning Force Microscope Using a Common-path Optical Heterodyne Interferometer.

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Improved common-path optical heterodyne interferometer for measuring small optical rotation angle of chiral medium

An improved common-path optical heterodyne interferometry for measuring small optical rotation angle of chiral liquid is presented. The optical rotation angle can be determined by the phase difference between the test and reference signals. By means of inserting a phase retarder behind the test sample, the measuring resolution of optical rotation angle is greatly enhanced. The theoretical predi...

متن کامل

Heterodyne common-path grating interferometer with Littrow configuration.

This paper presents a heterodyne common-path grating interferometer with Littrow configuration (HCGIL). The HCGIL can effectively overcome environmental disturbance effect and the DC offset and the amplitude variation of the measurement signals. Experimental results match well with the HP5529A results for long-range measurements. Results also show that the estimated measurement resolution is 0....

متن کامل

Heterodyne interferometer with unequal path lengths

Laser interferometry is an extensively used diagnostic for plasma experiments. Existing plasma interferometers are designed on the presumption that the scene and reference beam path lengths have to be equal, a requirement that is costly in both the number of optical components and the alignment complexity. It is shown here that having equal path lengths is not necessary, instead, what is requir...

متن کامل

Space position measurement using long-path heterodyne interferometer with optical frequency comb.

A heterodyne interference system was developed for position measurement. A stabilized optical-frequency comb is used as the laser source. The preliminary experiment to measure a distance of 22.478 m shows a drift of 1.6 μm in 20 minutes after the temperature compensation. Comparison and frequency shift experiments have been done for a distance of about 7.493 m. The experimental results show tha...

متن کامل

Improved technique for measuring full-field absolute phases in a common-path heterodyne interferometer.

When an asymmetric triangle voltage signal is applied to drive an electro-optic modulator, interference signals with two groups of periodic sinusoidal segments with different frequencies are obtained. An improved method is proposed to fit these two groups of segments, and their associated phases can be determined. The absolute phase can be obtained by subtracting the initial phase from the phas...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of the Japan Society for Precision Engineering

سال: 1993

ISSN: 1882-675X,0912-0289

DOI: 10.2493/jjspe.59.1853