Scanned Single-Electron Probe inside a Silicon Electronic Device
نویسندگان
چکیده
منابع مشابه
Scanned probe imaging of quantum dots inside InAs nanowires.
We show how a scanning probe microscope (SPM) can be used to image electron flow through InAs nanowires, elucidating the physics of nanowire devices on a local scale. A charged SPM tip is used as a movable gate. Images of nanowire conductance versus tip position spatially map the conductance of InAs nanowires at liquid-He temperatures. Plots of conductance versus backgate voltage without the ti...
متن کاملPretreatment quality control of single isocenter half- beam treatment planning technique using an amorphous silicon electronic portal-imaging device (EPID)
Introduction: Electronic portal imaging devices (EPIDs) are fundamentally used for instantaneous verification of the patient set‐up, block shape, and leaf positions during radiation therapy. In radiotherapy, situations arise in which an inclined PTV must be treated mutually with adjacent nodal regions. This methodology is most widely used for matching tangential/lateral breas...
متن کاملScanned probe imaging of single-electron charge states in nanotube quantum dots.
An atomic force microscope was used to study single-electron motion in nanotube quantum dots. By applying a voltage to the microscope tip, the number of electrons occupying the quantum dot could be changed, causing Coulomb oscillations in the nanotube conductance. Spatial maps of these oscillations were used to locate individual dots and to study the electrostatic coupling between the dot and t...
متن کاملScanned probe microscopy of electronic transport in carbon nanotubes.
We use electrostatic force microscopy and scanned gate microscopy to probe the conducting properties of carbon nanotubes at room temperature. Multiwalled carbon nanotubes are shown to be diffusive conductors, while metallic single-walled carbon nanotubes are ballistic conductors over micron lengths. Semiconducting single-walled carbon nanotubes are shown to have a series of large barriers to co...
متن کاملScanned-probe detection of electron spin resonance from a nitroxide spin probe SUPPORTING INFORMATION
The sample was prepared by dissolving 0.0063 g of TEMPAMINE (4-amino-2,2,6,6-tetramethylpiperidine-1oxyl; Aldrich, 163945) in 1 mL of d8-toluene, 0.33 mL of which was further diluted to 1 mL and from that, a 0.1 mL alliquot was added to a solution of 0.039 g deuterated polystyrene (Polymer Source, P4179B-dPS, Mn = 200×10 and Mw/Mn = 1.4) in 0.9 mL of d8-toluene. The resulting solution was spun ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: ACS Nano
سال: 2020
ISSN: 1936-0851,1936-086X
DOI: 10.1021/acsnano.0c00736