Scaling studies of spheromak formation and equilibrium
نویسندگان
چکیده
منابع مشابه
Scaling Studies of Spheromak Formation and Equilibrium
Formation and equilibrium studies have been performed on the Swarthmore Spheromak Experiment (SSX). Spheromaks are formed with a magnetized coaxial plasma gun and equilibrium is established in both small (dsmall = 0.16 m) and large (dlarge = 3dsmall = 0.50 m) copper flux conservers. Using magnetic probe arrays we have verified that spheromak formation is governed solely by gun physics (in parti...
متن کاملsimulation and experimental studies for prediction mineral scale formation in oil field during mixing of injection and formation water
abstract: mineral scaling in oil and gas production equipment is one of the most important problem that occurs while water injection and it has been recognized to be a major operational problem. the incompatibility between injected and formation waters may result in inorganic scale precipitation in the equipment and reservoir and then reduction of oil production rate and water injection rate. ...
postnatal studies of bats (pipistrellus kuhlii and miniopterus schreibersii) & histomorphology and histochemistry studies of organs and diseases of (neurergus microspilotus and n. kaiseri)
1. to determine whether difference in birth body mass influenced growth performance in pipistrellus kuhlii we studied a total of 12 captive-born neonates. bats were assigned to two body mass groups: light birth body mass (lbw: 0.89 ± 0.05, n=8) and heavy birth body mass (hbw: 1.35 ± 0.08, n=4). heavier body mass at birth was associated with rapid postnatal growth (body mass and forearm length) ...
Spheromak formation and sustainment studies at the sustained spheromak physics experiment using high-speed imaging and magnetic diagnostics
A high-speed imaging system with shutter speeds as fast as 2 ns and double frame capability has been used to directly image the formation and evolution of the sustained spheromak physics experiment SSPX E. B. Hooper et al., Nucl. Fusion 39, 863 1999 . Reproducible plasma features have been identified with this diagnostic and divided into three groups, according to the stage in the discharge at ...
متن کاملFormation of a Spheromak Plasma Configuration
As seen in Fig. 1(a), the diabatic signal does indeed increase as the value of n increases. In addition, both ionization features are evident at slew rates differing by a factor of 2 from that used to obtain the data in Fig. 1. When both lasers are polarized parallel to the direction of the electric field, then theoretically no ~ m, ~ = 2 can be produced and, in this case, we observe a dramatic...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Physics of Plasmas
سال: 1998
ISSN: 1070-664X,1089-7674
DOI: 10.1063/1.872632