Sample Thickness Limitations in Defocused Electron Probe Ptychography
نویسندگان
چکیده
منابع مشابه
Sample Preparation for Electron Probe Microanalysis—Pushing the Limits
There are two fundamental considerations in preparing samples for electron probe microanalysis (EPMA). The first one may seem obvious, but we often find it is overlooked. That is, the sample analyzed should be representative of the population from which it comes. The second is a direct result of the assumptions in the calculations used to convert x-ray intensity ratios, between the sample and s...
متن کاملBig Data Analytics for Scanning Transmission Electron Microscopy Ptychography
Electron microscopy is undergoing a transition; from the model of producing only a few micrographs, through the current state where many images and spectra can be digitally recorded, to a new mode where very large volumes of data (movies, ptychographic and multi-dimensional series) can be rapidly obtained. Here, we discuss the application of so-called "big-data" methods to high dimensional micr...
متن کاملSample thickness determination by scanning transmission electron microscopy at low electron energies.
Sample thickness is a decisive parameter for any quantification of image information and composition in transmission electron microscopy. In this context, we present a method to determine the local sample thickness by scanning transmission electron microscopy at primary energies below 30 keV. The image intensity is measured with respect to the intensity of the incident electron beam and can be ...
متن کاملSingle-shot ptychography & sparsity-based subwavelength ptychography
We overcome two major limitations in ptychography – a powerful scanning-based coherent diffraction imaging technique. We demonstrate single-shot ptychography, overcoming the scanning-limited temporal resolution and also demonstrate sparsity-based subwavelength ptychography, overcoming the Abbe spatial resolution limit. OSCI: Phase retrieval: 100.5070; Scanning microscopy: 180.5810; Computationa...
متن کاملHolographic recording in acrylamide photopolymers: thickness limitations.
Holographic recording in thick photopolymer layers is important for application in holographic data storage, volume holographic filters, and correlators. Here, we studied the characteristics of acrylamide-based photopolymer layers ranging in thickness from 250 microm to 1 mm. For each thickness, samples with three different values of absorbance were studied. By measuring the diffraction efficie...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Microscopy and Microanalysis
سال: 2018
ISSN: 1431-9276,1435-8115
DOI: 10.1017/s1431927618001435