Sample Dependent Resolution of Transmission Electron Microscopy in Water or Ice
نویسندگان
چکیده
منابع مشابه
Transmission Electron Microscopy Sample Preparation of INCONEL 738 Nickel-Base Superalloy
Size, shape, volume fraction and distribution of embedded g/ phase in g phase has direct effect on strength of INCONEL alloy. Microstructure parameters of INCONEL phases are quantified from microstructure images using transmission electron microscopy (TEM). Different TEM sample preparation techniques were used to study INCONEL 738 alloy microstructure for transmission electron micros...
متن کاملHigh-resolution transmission electron microscopy
High-resolution transmission electron microscopy (HRTEM) has been widely and effectively used for analyzing crystal structures and lattice imperfections in various kinds of advanced materials on an atomic scale. This is especially the case for high Tc superconductors (HTSCs). The most characteristic feature in crystal structures of HTSCs is that there is a common structural element, a CuO2 plan...
متن کاملScanning transmission electron microscopy at high resolution.
We have shown that a scanning transmission electron microscope with a high brightness field emission source is capable of obtaining better than 3 A resolution using 30 to 40 keV electrons. Elastic dark field images of single atoms of uranium and mercury are shown which demonstrate this fact as determined by a modified Rayleigh criterion. Point-to-point micrograph resolution between 2.5 and 3.0 ...
متن کاملStatistical Experimental Design for Quantitative Atomic Resolution Transmission Electron Microscopy Statistical Experimental Design for Quantitative Atomic Resolution Transmission Electron Microscopy
Dr. ir. A.J. den Dekker heeft als begeleider in belangrijke mate aan de totstandkoming van het proefschrift bijgedragen.
متن کاملThermal magnetic field noise limits resolution in transmission electron microscopy.
The resolving power of an electron microscope is determined by the optics and the stability of the instrument. Recently, progress has been obtained towards subångström resolution at beam energies of 80 kV and below but a discrepancy between the expected and achieved instrumental information limit has been observed. Here we show that magnetic field noise from thermally driven currents in the con...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Microscopy and Microanalysis
سال: 2018
ISSN: 1431-9276,1435-8115
DOI: 10.1017/s1431927618010371