Sample delivery using viscous media, a syringe and a syringe pump for serial crystallography
نویسندگان
چکیده
منابع مشابه
Open-Source Syringe Pump Library
This article explores a new open-source method for developing and manufacturing high-quality scientific equipment suitable for use in virtually any laboratory. A syringe pump was designed using freely available open-source computer aided design (CAD) software and manufactured using an open-source RepRap 3-D printer and readily available parts. The design, bill of materials and assembly instruct...
متن کاملUser preference for a portable syringe pump for iloprost infusion
PURPOSE Administration of intravenous iloprost - a first-line European League Against Rheumatism (EULAR)-recommended choice for the treatment of scleroderma (SSc)-related digital vasculopathy - requires repeated treatment cycles of 6 hours per day in a hospital setting. During the infusion, patient mobility is considerably restricted due to the size and fixity of traditional syringe pumps. The ...
متن کاملLiquid sample delivery techniques for serial femtosecond crystallography.
X-ray free-electron lasers overcome the problem of radiation damage in protein crystallography and allow structure determination from micro- and nanocrystals at room temperature. To ensure that consecutive X-ray pulses do not probe previously exposed crystals, the sample needs to be replaced with the X-ray repetition rate, which ranges from 120 Hz at warm linac-based free-electron lasers to 1 M...
متن کاملViscous hydrophilic injection matrices for serial crystallography
Serial (femtosecond) crystallography at synchrotron and X-ray free-electron laser (XFEL) sources distributes the absorbed radiation dose over all crystals used for data collection and therefore allows measurement of radiation damage prone systems, including the use of microcrystals for room-temperature measurements. Serial crystallography relies on fast and efficient exchange of crystals upon X...
متن کاملCalibration of pneumotachographs using a calibrated syringe.
Pneumotachograph require frequent calibration. Constant-flow methods allow polynomial calibration curves to be derived but are time consuming. The iterative syringe stroke technique is moderately efficient but results in discontinuous conductance arrays. This study investigated the derivation of first-, second-, and third-order polynomial calibration curves from 6 to 50 strokes of a calibration...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Synchrotron Radiation
سال: 2019
ISSN: 1600-5775
DOI: 10.1107/s160057751900897x