Safety of implantable Collamer lens implantation without ophthalmic viscosurgical device

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Intraocular pressure after implantation of the Visian Implantable Collamer Lens With CentraFLOW without iridotomy.

PURPOSE To compare the intraocular pressure (IOP) values during a 3-month period after implantation of the new Visian Implantable Collamer Lens (ICL; STAAR Surgical Company, Nidau, Switzerland) V4c design with CentraFLOW technology without iridotomy using a standard procedure followed by implantation of the conventional ICL V4b model. DESIGN Retrospective cohort study. METHODS This study in...

متن کامل

Implantable Collamer Lens Versus Iris-Fixed Phakic Intraocular Lens Implantation to Correct Myopia: A Meta-Analysis

This study is a meta-analysis comparing the efficacy, predictability, and safety of correcting myopia via implantation of two types of phakic intraocular lens (PIOLs): the implantable collamer lens (ICL) and iris-fixed PIOL. The Cochrane library, Pubmed, and EMBASE were searched. Study selection, data exclusion, and quality assessment were performed by two independent observers. The pooled rela...

متن کامل

Ophthalmic viscosurgical device backflow into cartridge during intraocular lens insertion using injectors

BACKGROUND The purpose of this study was to assess the risk of intraocular contamination caused by intraocular lens (IOL) insertion with injectors by observing the dynamics of an ophthalmic viscosurgical device (OVD). METHODS Each type of injector was equipped with a colored OVD and IOL, and a 2 mm length from the tip of the cartridge was replaced with a colored OVD. The various combinations ...

متن کامل

Implantation of an implantable collamer lens and iris cerclage for the treatment of Urrets-Zavalia syndrome

A 27-year-old woman with bilateral high myopia had anterior chamber iris-claw phakic intraocular lens implantation in her left eye under local anesthesia and with no intraoperative complications. The preoperative slit-lamp examination was normal, and she had no relevant past medical history. On the second postoperative day, patient developed fixed, dilated mydriasis, and one month later, an IOL...

متن کامل

Posterior Vitreous Detachment and Retinal Detachment After Implantation of the Visian Phakic Implantable Collamer Lens

INTRODUCTION To evaluate the vitreoretinal complications in myopes after Visian implantable collamer lenses (ICL) implantation. MATERIALS AND METHODS This is a retrospective, observational, non-comparative clinical study that evaluated 617 consecutive myopes who underwent ICL implantation at the Department of Refractive Surgery, Yemen Magrabi Hospital, Sana'a, Yemen between July 2006 and May ...