Safety of implantable Collamer lens implantation without ophthalmic viscosurgical device
نویسندگان
چکیده
منابع مشابه
Intraocular pressure after implantation of the Visian Implantable Collamer Lens With CentraFLOW without iridotomy.
PURPOSE To compare the intraocular pressure (IOP) values during a 3-month period after implantation of the new Visian Implantable Collamer Lens (ICL; STAAR Surgical Company, Nidau, Switzerland) V4c design with CentraFLOW technology without iridotomy using a standard procedure followed by implantation of the conventional ICL V4b model. DESIGN Retrospective cohort study. METHODS This study in...
متن کاملImplantable Collamer Lens Versus Iris-Fixed Phakic Intraocular Lens Implantation to Correct Myopia: A Meta-Analysis
This study is a meta-analysis comparing the efficacy, predictability, and safety of correcting myopia via implantation of two types of phakic intraocular lens (PIOLs): the implantable collamer lens (ICL) and iris-fixed PIOL. The Cochrane library, Pubmed, and EMBASE were searched. Study selection, data exclusion, and quality assessment were performed by two independent observers. The pooled rela...
متن کاملOphthalmic viscosurgical device backflow into cartridge during intraocular lens insertion using injectors
BACKGROUND The purpose of this study was to assess the risk of intraocular contamination caused by intraocular lens (IOL) insertion with injectors by observing the dynamics of an ophthalmic viscosurgical device (OVD). METHODS Each type of injector was equipped with a colored OVD and IOL, and a 2 mm length from the tip of the cartridge was replaced with a colored OVD. The various combinations ...
متن کاملImplantation of an implantable collamer lens and iris cerclage for the treatment of Urrets-Zavalia syndrome
A 27-year-old woman with bilateral high myopia had anterior chamber iris-claw phakic intraocular lens implantation in her left eye under local anesthesia and with no intraoperative complications. The preoperative slit-lamp examination was normal, and she had no relevant past medical history. On the second postoperative day, patient developed fixed, dilated mydriasis, and one month later, an IOL...
متن کاملPosterior Vitreous Detachment and Retinal Detachment After Implantation of the Visian Phakic Implantable Collamer Lens
INTRODUCTION To evaluate the vitreoretinal complications in myopes after Visian implantable collamer lenses (ICL) implantation. MATERIALS AND METHODS This is a retrospective, observational, non-comparative clinical study that evaluated 617 consecutive myopes who underwent ICL implantation at the Department of Refractive Surgery, Yemen Magrabi Hospital, Sana'a, Yemen between July 2006 and May ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Medicine
سال: 2020
ISSN: 0025-7974,1536-5964
DOI: 10.1097/md.0000000000020691