Safety and efficacy of a modified axillary vein technique for pacemaker implantation
نویسندگان
چکیده
منابع مشابه
Left axillary pacemaker generator implantation with a direct puncture of the left axillary vein.
BACKGROUND Pacemaker generators are routinely implanted in the anterior chest. However, where to place the generator may need to be considered from the mental, functional, and cosmetic standpoints. METHODS In this study, we performed the left axillary pacemaker generator implantation with a direct puncture of the left axillary vein in 40 consecutive patients, and evaluated the late safety and...
متن کاملAxillary vein puncture without contrast venography for pacemaker and defibrillator leads implantation.
BACKGROUND Axillary vein puncture has been demonstrated to be an effective method for pacemaker and defibrillator leads implantation, without the complications encountered with the standard intrathoracic approach. OBJECTIVE Different techniques have been adopted for the cannulation of the axillary vein. We report our experience using the outer edge of the first rib below the inferior border o...
متن کاملVenous spasm during contrast-guided axillary vein puncture for pacemaker or defibrillator lead implantation.
AIMS Contrast-guided axillary vein puncture is commonly used for pacemaker or defibrillator lead implantation. Venous spasm during contrast-guided axillary vein puncture has been reported rarely. We investigated the incidence of venous spasm during contrast-guided axillary vein puncture and the impact of venous spasm on axillary vein puncture. METHODS AND RESULTS Seventy-four consecutive pati...
متن کاملSafety, Efficacy and Clinical Outcome of Direct Stent Implantation
Conventional methods of stenting require predilatation, which potentially increase vessel wall injury and cost of the procedure. In this study, the safety and efficacy of direct AVE-S7 (Medtronic-USA) stent placement were evaluated in 100 patients. Quantitative coronary angiography was performed at the baseline and post-stent. Clinical follow-up was done up to 9 months. In 100 patients (76 male...
متن کاملIatrogenic brachiocephalic vein perforation during pacemaker implantation.
To cite: Nakabayashi K. BMJ Case Rep Published online: [please include Day Month Year] doi:10.1136/ bcr-2015-209369 DESCRIPTION An 82-year-old man with chronic obstructive pulmonary disease received a pacemaker implantation because of his advanced atrioventricular block. We smoothly inserted two sheaths by extrathoracic puncture into the left subclavian region. Mild resistance appeared at the p...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Cardiology Plus
سال: 2018
ISSN: 2470-7511
DOI: 10.4103/cp.cp_21_18