Routine Fixation of Weber B Fibula Fractures with a Lateral Locking Plate and No Lag Screw

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

First Metatarsophalangeal Joint Arthrodesis: A Retrospective Comparison of Crossed-screws, Locking and Non-Locking Plate Fixation with Lag Screw

Background:Locking plate fixation is increasingly used for first metatarsophalangeal joint (MTP-I) arthrodesis. Still there is few comparable clinical data regarding this procedure. Methods:We retrospectively evaluated 60 patients who received an arthrodesis of the MTP-I between January 2008 and June 2010. With 20 patients each we performed a locking plate fixation with lag screw, arthrodesis w...

متن کامل

First Metatarsophalangeal Joint Arthrodesis: A Retrospective Comparison of Crossed-screws, Locking and Non-Locking Plate Fixation with Lag Screw

Background:Locking plate fixation is increasingly used for first metatarsophalangeal joint (MTP-I) arthrodesis. Still there is few comparable clinical data regarding this procedure. Methods:We retrospectively evaluated 60 patients who received an arthrodesis of the MTP-I between January 2008 and June 2010. With 20 patients each we performed a locking plate fixation with lag screw, arthrodesis w...

متن کامل

A Pitfall in Fixation of Distal Humeral Fractures with Pre-Contoured Locking Compression Plate

Anatomically precontoured locking plates are intended to facilitate the fixation of articular fractures and particularly those associated with osteoporosis. Fractures of the distal humerus are relatively uncommon injuries where operative intervention can be exceptionally challenging. The distal humeral trochlea provides a very narrow anatomical window through which to pass a fixed-angle locking...

متن کامل

Precontoured locking plate fixation for displaced lateral clavicle fractures.

Displaced fractures of the lateral end of the clavicle are associated with an increased risk of nonunion with conservative treatment; therefore, operative treatment is recommended. Various operative treatments have been suggested, but no consensus exists regarding a gold standard for the surgical treatment of this type of fracture. The purpose of this study was to evaluate clinical and radiolog...

متن کامل

Gravity Reduction View: A Radiographic Technique for the Evaluation and Management of Weber B Fibula Fractures

Background: While various radiographic parameters and application of manual/gravity stress have been proposed to elucidate instability for Weber B fibula fractures, the prognostic capability of these modalities remains unclear. Determination of anatomic positioning of the mortise is paramount. We propose a novel view, the Gravity Reduction View (GRV), which helps elucidate non-anatomic position...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Foot & Ankle Orthopaedics

سال: 2020

ISSN: 2473-0114,2473-0114

DOI: 10.1177/2473011420s00140