OBJECTIVE/HYPOTHESIS Previous reports have documented the feasibility of utilizing electrocochleographic (ECoG) responses to acoustic signals to assess trauma caused during cochlear implantation. The hypothesis is that intraoperative round window ECoG before and after electrode insertion will help predict postoperative hearing preservation outcomes in cochlear implant recipients. STUDY DESIGN...
متن کاملEvaluation of Intracochlear Trauma Caused by Insertion of Cochlear Implant Electrode Arrays through Different Quadrants of the Round Window
HYPOTHESIS This study aimed to evaluate whether there is a difference in the degree of intracochlear trauma when the cochlear implant electrode arrays is inserted through different quadrants of the round window membrane. BACKGROUND The benefits of residual hearing preservation in cochlear implant recipients have promoted the development of atraumatic surgeries. Minimal trauma during electrode...
متن کاملA novel perfusion-based method for cochlear implant electrode insertion.
A cochlear implant (CI) restores partial hearing to profoundly deaf individuals. CI electrodes are inserted manually in the cochlea and surgeons rely on tactile feedback from the implant to determine when to stop the insertion. This manual insertion method results in a large degree of variability in surgical outcomes and intra-cochlear trauma. Additionally, implants often span only the basal tu...
متن کاملA cochlear implant electrode.
This study has shown that an electrode array can be passed along the hold length of the cochlea if it is inserted through and opening in the scala tympani of the apical turn. The electrode must have the appropriate mechanical properties and some of these were stiffness and extensibility. The electrode and operative approach should be helpful in stimulating the terminal auditory nerve fibres on ...
متن کاملExtra- and Intracochlear Electrocochleography in Cochlear Implant Recipients.
OBJECTIVE To monitor cochlear function by extra- and intra-cochlear electrocochleography (ECoG) during and after cochlear implantation and thereby to enhance the understanding of changes in cochlear function following cochlear implantation surgery. METHODS ECoG responses to acoustic stimuli of 250, 500 and 1,000 Hz were recorded in 9 cochlear implant recipients with presurgical residual heari...