Rotational Resistance of Surface-Treated Mini-Implants

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Rotational resistance of surface-treated mini-implants.

OBJECTIVE To test the hypothesis that there is no difference in the stability and resistance to rotational moments of early loaded sandblasted and acid-etched (SLA) mini-implants and those of machined-surface implants of the same size and shape. MATERIALS AND METHODS A randomized complete block design was used in 12 skeletally mature male beagle dogs. Ninety-six orthodontic mini-implants were...

متن کامل

Resistance to immediate orthodontic loading of surface-treated mini-implants.

OBJECTIVE To test the hypothesis that there is no difference in the stability and resistance to orthodontic forces of immediately loaded sandblasted and acid-etched (SAE) mini-implants and those of machined-surface implants of the same size and shape. MATERIALS AND METHODS Two types of mini-implants were used in the tibiae of 44 rabbits; some had an SAE surface and some had machined surfaces....

متن کامل

Laser-treated stainless steel mini-screw implants: 3D surface roughness, bone-implant contact, and fracture resistance analysis.

BACKGROUND/OBJECTIVES This study investigated the biomechanical properties and bone-implant intersurface response of machined and laser surface-treated stainless steel (SS) mini-screw implants (MSIs). MATERIAL AND METHODS Forty-eight 1.3mm in diameter and 6mm long SS MSIs were divided into two groups. The control (machined surface) group received no surface treatment; the laser-treated group ...

متن کامل

Evaluation of Stability of Surface-Treated Mini-Implants in Diabetic Rabbits

Introduction. The purpose of this study was to investigate effects of surface treatment of mini-implants in diabetes-induced rabbits by comparing osseointegration around mini-implants. Methods. Twelve New Zealand white rabbits were divided into two groups (alloxan-induced diabetic group and control group). A total of 48 mini-implants were placed after four weeks of diabetic induction. 24 mini-i...

متن کامل

Bone cutting capacity and osseointegration of surface-treated orthodontic mini-implants

OBJECTIVE The objective of the study was to evaluate the practicality and the validity of different surface treatments of self-drilling orthodontic mini-implants (OMIs) by comparing bone cutting capacity and osseointegration. METHODS Self-drilling OMIs were surface-treated in three ways: Acid etched (Etched), resorbable blasting media (RBM), partially resorbabla balsting media (Hybrid). We co...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: The Angle Orthodontist

سال: 2009

ISSN: 0003-3219,1945-7103

DOI: 10.2319/090608-466.1