Rotation Capacity of Bolted Flush End-Plate Stiffened Beam-to-Column Connection
نویسندگان
چکیده
منابع مشابه
Numerical Analysis of End Plate Bolted Connection with Corrugated Beam
Steel extended end plate bolted connections are recommended to be widely utilized in special moment-resisting frame subjected to monotonic loading. Improper design of steel beam to column connection can lead to the collapse and fatality of structures. Therefore comprehensive research studies of beam to column connection design should be carried out. Also the performance and effect of corrugated...
متن کاملA Review on Finite Element Analysis of Beam to Column Endplate Bolted Connection
This paper gives a bibliographical review of the methods which are applied for the analysis of Beam to column bolted end plate connection from the theoretical as well as practical points of view. The bibliography at the end of the paper contains 84 references of papers and conference proceedings on the subject that were published between 1914 and 2011. These are classified in the following cate...
متن کاملEvaluation of Column-Tree Moment Resisting Connection with End Plates and Haunched Beam (RESEARCH NOTE)
The column-tree constructional schemes allows for a reliable and convenient erection of moment resisting steel frames. Strengthening of column-tree connection with a haunch part can significantly improve seismic behavior of whole system. In the current study behavior of column-tree connections with haunched beams and end plate splices have been investigated. Special attention was paid for evalu...
متن کاملNumerical Analysis of Cyclic Behavior of Beam-To-Column Bolted Connections in Steel Frames
This article considers the seismic behavior of beam-to-column joints in steel frames for different bolt arrangements by using of finite element modeling. As the most important beam-to-column joint type, the beam-to-column joints with end-plate is chosen for the analysis. Four different specimens have been analyzed. These models had some differences such as bolt arrangement and the presence or a...
متن کاملA Study on the Ductility of Bolted Beam - Column Connections
The behaviour of beam-column joint plays an important role in the response of a steel moment resisting framed structure especially under seismic excitation. Semi rigid connections like bolted joints, allow better energy dissipation and provide good response under lateral loads. In this paper the ductility and energy dissipation characteristics of semi rigid bolted connections using double web a...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Civil and Environmental Engineering Reports
سال: 2017
ISSN: 2450-8594,2080-5187
DOI: 10.1515/ceer-2017-0028