Robust Time-Varying Load Modeling for Conservation Voltage Reduction Assessment
نویسندگان
چکیده
منابع مشابه
Energy Saving of Conservation Voltage Reduction Based on Load-Voltage Dependency
Abstract: Reducing voltage to reduce energy consumption, referred to as conservation voltage reduction (CVR), can lead to energy savings. Calculating the effects of reducing voltage requires accurate load models. This paper investigates a load-voltage dependency factor that can be measured via field experiments using common existing instrumentation. A relationship between the load-voltage depen...
متن کاملStationarity assessment with time-varying autoregressive modeling
A new method for assessing the stationarity of a signal is addressed. The proposed technique is based on the application of time-varying autoregressive models, in which coe cient variations are decomposed upon a set of deterministic basis functions. Stationarity is evaluated by selecting the optimal number of basis functions with a generalized version of Minimum Description Length criterion. Re...
متن کاملA Robust Adaptive Observer-Based Time Varying Fault Estimation
This paper presents a new observer design methodology for a time varying actuator fault estimation. A new linear matrix inequality (LMI) design algorithm is developed to tackle the limitations (e.g. equality constraint and robustness problems) of the well known so called fast adaptive fault estimation observer (FAFE). The FAFE is capable of estimating a wide range of time-varying actuator fault...
متن کاملTime-Varying Robust Queueing
Authors are encouraged to submit new papers to INFORMS journals by means of a style file template, which includes the journal title. However, use of a template does not certify that the paper has been accepted for publication in the named journal. INFORMS journal templates are for the exclusive purpose of submitting to an INFORMS journal and should not be used to distribute the papers in print ...
متن کاملEvaluation of the Effects of Nationwide Conservation Voltage Reduction on Peak-Load Shaving Using SOMAS Data
In this paper we propose a new method to evaluate the effects of nationwide conservation voltage reduction (CVR) on peak-load shaving, using substation operating results management system (SOMAS) data. Its evaluation is based on a national CVR factor, which is defined as the weighted average of CVR factors associated with all transformer banks and weighting coefficients are determined by the re...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: IEEE Transactions on Smart Grid
سال: 2018
ISSN: 1949-3053,1949-3061