Detection and Quantification of Control Valve Stiction
Stiction is one of the most common problems in the spring-diaphragm type control valves, which are widely used in the process industry. Although there have been many attempts to understand and detect stiction in control valves, none of the current methods can simultaneously detect and quantify stiction. There is thus a clear need in the process industry for a non-invasive method that can not on...
متن کاملPractical Model and Detection Algorithm for Valve Stiction
Stiction is the most common problem in pneumatic control valves, which are widely used in the process industry. Stiction causes fluctuation of process variables, which lowers productivity. Therefore, developing a method to detect stiction and distinguish it from other causes is crucial to help operators take an appropriate action for improving control performance. The present work proposes a va...
متن کاملislanding detection methods for microgrids
امروزه استفاده از منابع انرژی پراکنده کاربرد وسیعی یافته است . اگر چه این منابع بسیاری از مشکلات شبکه را حل می کنند اما زیاد شدن آنها مسائل فراوانی برای سیستم قدرت به همراه دارد . استفاده از میکروشبکه راه حلی است که علاوه بر استفاده از مزایای منابع انرژی پراکنده برخی از مشکلات ایجاد شده توسط آنها را نیز منتفی می کند . همچنین میکروشبکه ها کیفیت برق و قابلیت اطمینان تامین انرژی مشترکان را افزایش ...
15 صفحه اولValve backlash and stiction detection in integrating processes
Valve nonlinearities are responsible for producing limit cycles in the loop and consequently decreasing plant performance. In the case of an integrating plant, once the loop oscillation is detected, the engineer should distinguish between stiction and backlash, but no method is available in the literature to address this class of problem. In this paper, it is proposed a data-driven method to di...
متن کاملDetection of power oscillation and simultaneous faults using Clark transform
Distance relays are widely used to protect transmission lines. Sometimes, in these lines due to the occurrence of the oscillation of the power, the impedance calculated in the distance relay enters into its functional zones and leads to the cutting off of the lines. This issue can cause global power outages. Accordingly, in this paper, a Clark-based method for detecting the oscillation of power...