Robust optimization of multi-probe roundness measurement probe angles
نویسندگان
چکیده
Positional errors of a multi-probe roundness measurement frame will result in the probe angles deviating from nominal angles. The actual can be accurately determined after placing using cross correlation or other methods. However, since methods suffer harmonic suppression, determining is not enough for accurate reconstruction profile, if are situated an area with poor characteristics. To find suitable areas to allow deviations angles, this paper presents robust optimization avoid suppression regardless Suggestions optimal presented three-point and four-point redundant diameter method.
منابع مشابه
Profile Measurement of Resist Surface Using Multi-Array-Probe System
Semiconductor processing in manufacturing must be fast and highly accurate in the measuring of the surface profile of soft thin films such as photoresist. Since photoresist surface is very smooth and deformable, a device to measure is required that will measure vertical direction with a nanometer resolution in height and not damage the film during the measurement. To do this, we developed an ap...
متن کاملDesign and Simulation of piezorestive pressure sensor for AFM Probe the displacement measurement
investigating pressure applied in surface vertically that is done by use of mechanical procedures isn’t efficient to measure pressure applied in inner surface of reservoir or pipes having gas due to entering pressure into whole walls and different surfaces. So, in order to measure this kind of pressure, several studies were conducted in past decades and also various procedures were proposed tha...
متن کاملMulti-probe consistent hashing
1 Abstract We describe a consistent hashing algorithm which performs multiple lookups per key in a hash table of nodes. It requires no additional storage beyond the hash table, and achieves a peak-to-average load ratio of 1 + ε with just 1 + 1 ε lookups per key.
متن کاملSWI: Probe for neuroradiologists
Susceptibility-weighted imaging (SWI) has continued to develop into a powerful clinical tool to visualize venous structures and iron in the brain and to study diverse pathologic conditions. It is a new art which evaluates and exploits the properties of blood, iron and other tissues. It is a magnitude or filtered phase images or combination of both, obtained with high-resolution 3D fully velocit...
متن کاملSWI: Probe for neuroradiologists
Susceptibility-weighted imaging (SWI) has continued to develop into a powerful clinical tool to visualize venous structures and iron in the brain and to study diverse pathologic conditions. It is a new art which evaluates and exploits the properties of blood, iron and other tissues. It is a magnitude or filtered phase images or combination of both, obtained with high-resolution 3D fully velocit...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Measurement
سال: 2021
ISSN: ['1873-412X', '0263-2241']
DOI: https://doi.org/10.1016/j.measurement.2020.108146