Robust Fault-Tolerant Synergetic Control for Dual Three-Phase PMSM Drives Considering Speed Sensor Fault
نویسندگان
چکیده
منابع مشابه
Current Sensor Fault Reconstruction for PMSM Drives
This paper deals with a current sensor fault reconstruction algorithm for the torque closed-loop drive system of an interior PMSM. First, sensor faults are equated to actuator ones by a new introduced state variable. Then, in αβ coordinates, based on the motor model with active flux linkage, a current observer is constructed with a specific sliding mode equivalent control methodology to elimina...
متن کاملExperimental fault-tolerant control of a PMSM drive
The paper describes a study and an experimental verification of remedial strategies against failures occurring in the inverter power devices of a permanent-magnet synchronous motor drive. The basic idea of this design consists in incorporating a fourth inverter pole, with the same topology and capabilities of the other conventional three poles. This minimal redundant hardware, appropriately con...
متن کاملFault Diagnosis and Fault-Tolerant SVPWM Technique of Six-phase Converter under Open-Switch Fault
In this paper, a new open-switch fault diagnosis method is proposed for the six-phase AC-DC converter based on the difference between the phase current and the corresponding reference using an adaptive threshold. The open-switch faults are detected without any additional equipment and complicated calculations, since the proposed fault detection method is integrated with the controller required ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: IEEE Access
سال: 2020
ISSN: 2169-3536
DOI: 10.1109/access.2020.2989821