Robotic Mirror Therapy System for Functional Recovery of Hemiplegic Arms

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evolution of robotic arms

The foundation of surgical robotics is in the development of the robotic arm. This is a thorough review of the literature on the nature and development of this device with emphasis on surgical applications. We have reviewed the published literature and classified robotic arms by their application: show, industrial application, medical application, etc. There is a definite trend in the manufactu...

متن کامل

Effect of Mirror Therapy on the Motor Recovery in Patients After Stroke: A Randomized Clinical Trial

Objectives: One of the most important problems seen in patients after stroke is that they cannot develop normal muscle strength. In recent years, the use of Mirror Therapy (MT) in the recovery of this condition has been noticed in different studies. This study investigated the effect of MT on motor recovery in patients after stroke. Methods: In this clinical trial, 93 patients were divided int...

متن کامل

A functional electric stimulation-assisted exercise therapy system for hemiplegic hand function.

OBJECTIVE To test a functional electric stimulation (FES)-assisted exercise therapy system for improvement of motor function of the hemiplegic upper extremity. DESIGN A before-after trial, with 2-month follow-up. SETTING A university research laboratory. PARTICIPANTS A convenience sample of 6 subjects (3 men, 3 women). Main inclusion criteria were that stroke had occurred more than 1 year...

متن کامل

Recovery of Proprioception in the Upper Extremity by Robotic Mirror Therapy: a Clinical Pilot Study for Proof of Concept

A novel robotic mirror therapy system was recently developed to provide proprioceptive stimulus to the hemiplegic arm during a mirror therapy. Validation of the robotic mirror therapy system was performed to confirm its synchronicity prior to the clinical study. The mean error angle range between the intact arm and the robot was 1.97 to 4.59 degrees. A 56-year-old male who had right middle cere...

متن کامل

Arms Control of Robotic Weapons

Digital Object Identifier 10.1109/MTS.2009.931862 W ith the development of the General Atomics MQ-1 Predator, robotic weapons came of age. The operations of this Unmanned Aerial Vehicle (UAV) in Iraq, Afghanistan, Pakistan, and northern Africa in the last few years have given us a glimpse of the future of high-tech war [6], [14], [24]. It is a future in which thousands of miles separate those f...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of Visualized Experiments

سال: 2016

ISSN: 1940-087X

DOI: 10.3791/54521