RM 8111: Development of a Prototype Linewidth Standard

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

RM 8111: Development of a Prototype Linewidth Standard

Staffs of the Semiconductor Electronics Division, the Information Technology Laboratory, and the Precision Engineering Laboratory at NIST, have developed a new generation of prototype Single-Crystal CD (Critical Dimension) Reference (SCCDRM) Materials with the designation RM 8111. Their intended use is calibrating metrology instruments that are used in semiconductor manufacturing. Each referenc...

متن کامل

Development of Prototype Iranian male pelvic phantom for internal dosimetry

Introduction: Existing phantoms have been constructed based on Caucasian, non-Caucasian and race-specific datasets. According to previous studies made efforts to present Korean- specific phantoms and Chinese female phantom based on CVH dataset due to compare the resulting internal dosimetry with the Caucasian based data showed possible racial difference in human anatomy between ...

متن کامل

Model Object of Rm - Odp Standard in Dynamic Distributed Databases

Distributed databases have invested considerable effort and system resources in the development and adoption of dynamic distributed databases services. In order to sustain the quality of their services, Business process management need to solve the problem of efficient and secure electronic exchange and processing of system database. A major difficulty in this distributed deployment is the fact...

متن کامل

Development of a prototype stereotactic collimation assembly for Neptun 10 PC linac

Background: A set of hardware stereotactic radiosurgery is designed and constructed. The scope of this article is to describe how we have designed and developed stereotactic collimation assembly for a 9 MV Neptun 10 PC linac. Materials and methods: One collimator holder and six collimators were made, with their radiation field diameter between 12.5 mm to 25 mm at isocenter level. Beam data, suc...

متن کامل

iranian efl learners’ pragmatic development: a study of proficiency and textbook effect

در تحقیق حاضراین پرسش که آیا دانش کاربرد شناسی زبان آموزان ایرانی همگام با پیشرفت بسندگی زبانی آنها افزایش می یابد مورد مطالعه قرار گرفته و هم چنین به این پرسش که آیا زبان آموزان تعلیم دیده از طریق کتاب های تاپ ناچ و اینترچینج تفاوت معناداری از لحاظ سطح دانش کاربرد شناسی دلرند ، پاسخ داده شده است. در این تحقیق55 فراگیر زبان انگلیسی به عنوان زبان دوم ازطریق نمونه گیری در دسترس مورد مطالعه قرار گ...

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of Research of the National Institute of Standards and Technology

سال: 2006

ISSN: 1044-677X

DOI: 10.6028/jres.111.016