Risk‐based many‐objective configuration of power system fault current limiters utilising NSGA‐III
نویسندگان
چکیده
منابع مشابه
Selection of Resistive and Inductive Superconductor Fault Current Limiters Location Considering System Transient Stability
Superconductor fault current limiter (SFCL) is an effective device to suppress high fault currents. This paper presents a comparative study of resistive and inductive fault current limiters from transient stability point of view. Appropriate location and type of the limiters in a HV substation is selected by a qualitative approach based on the equal area criterion. Study system is simulated by...
متن کاملFault Current Limiters – Principles and Application
In this paper a new type electrical devices, designed for use in medium voltage and high voltage grids, has been explained – the fault current limiters. Their principals of operation and different structures have been proposed. The comparative analysis and their possibile estimation have been made.
متن کاملselection of resistive and inductive superconductor fault current limiters location considering system transient stability
superconductor fault current limiter (sfcl) is an effective device to suppress high fault currents. this paper presents a comparative study of resistive and inductive fault current limiters from transient stability point of view. appropriate location and type of the limiters in a hv substation is selected by a qualitative approach based on the equal area criterion. study system is simulated by...
متن کاملPower flow analysis and optimal locations of resistive type superconducting fault current limiters
Based on conventional approaches for the integration of resistive-type superconducting fault current limiters (SFCLs) on electric distribution networks, SFCL models largely rely on the insertion of a step or exponential resistance that is determined by a predefined quenching time. In this paper, we expand the scope of the aforementioned models by considering the actual behaviour of an SFCL in t...
متن کاملThe Impact of Superconducting Fault Current Limiter Locations on Voltage Sag in Power Distribution System
In this paper, the impacts of installing superconducting fault current limiter (SFCL)in radial and loop power distribution system are evaluated to improve voltage sag in both cases of with and without distributed generations (DG). Among various SFCLs, the hybrid type with a superconducting element in parallel with a current limiting reactor (CLR) is selected. This is more effective than resisto...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: IET Generation, Transmission & Distribution
سال: 2020
ISSN: 1751-8687,1751-8695
DOI: 10.1049/iet-gtd.2020.0482