Risk of stent thrombosis among bare-metal stents, first-generation drug-eluting stents, and second-generation drug-eluting stents: results from a registry of 18,334 patients.

OBJECTIVES This study sought to compare the risk of stent thrombosis among patients treated with bare-metal stents (BMS), first-generation drug-eluting stents (G1-DES), and second-generation drug-eluting stents (G2-DES) for a period of 3 years. BACKGROUND In patients undergoing coronary stenting, there is a scarcity of long-term follow-up data on cohorts large enough to compare rates of stent...

متن کامل

Meta-analysis comparing drug-eluting stents with bare metal stents.

We performed a meta-analysis of 10 randomized trials of 5,066 patients with 6 to 12 months of follow-up. The summary risk differences excluded any major differences between the 2 types of stents for death (0.12%, 95% confidence interval [CI] -0.34% to 0.58%, p = 0.60) and overall myocardial infarction (0.04%, 95% CI -0.72% to 0.81%, p = 0.91). There was a modest increase in the risk of Q-wave m...

متن کامل

Drug-Eluting Versus Bare-Metal Stents

DR. STONE: Welcome to this roundtable discussion. Today, we’ll be focusing on some of the advantages, disadvantages, and nuances of drug-eluting and baremetal stents in the practice of interventional cardiology. My name is Gregg W. Stone; I’m an interventional cardiologist and Professor of Medicine at Columbia University Medical Center and the Cardiovascular Research Foundation in New York City...

متن کامل

Biodegradable polymer drug-eluting stents versus first-generation durable polymer drug-eluting stents

BACKGROUND Even if drug-eluting stents (DES) showed beneficial effects in patients with coronary artery diseases (CADs), limitations have been observed with the first-generation durable polymer DES (DP-DES). Recently, biodegradable polymer DES (BP-DES) have been approved to be used as an alternative to DP-DES, with potential benefits. We aimed to systematically compare BP-DES with the first-gen...