Risk of Pacemaker Patients by TASER X26 Contact Mode Application

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Risk of Pacemaker Patients by TASER X26 Contact Mode Application

The prevalence of pacemaker patients among the general population and of conducted energy devices (CED) for law enforcement and self-defence is increasing. Consequently, the question whether cardiac pacemaker (CPM) patients are on particular risk becomes increasingly important. The risk of Taser X26 electric interference with implanted CPM has been investigated by numerical simulation at MRI-ba...

متن کامل

Acute effects of TASER X26 discharges in a swine model.

BACKGROUND Very little objective laboratory data are available describing the physiologic effects of stun guns or electromuscular incapacitation devices (EIDs). Unfortunately, there have been several hundred in-custody deaths, which have been temporally associated with the deployment of these devices. Most of the deaths have been attributed to specific cardiac and metabolic effects. We hypothes...

متن کامل

The neuroendocrine effects of the TASER X26: a brief report.

INTRODUCTION Law enforcement officers use conducted electrical weapons (CEW) such as the TASER X26 to control violently resistive subjects. There are no studies in the medical literature examining the effects of these weapons on the human stress response. This is the first study to compare the human stress response to conducted electrical weapons, oleoresin capsicum (O.C.), a cold-water tank im...

متن کامل

Echocardiographic evaluation of a TASER-X26 application in the ideal human cardiac axis.

OBJECTIVES TASER electronic control devices (ECDs) are used by law enforcement to subdue aggressive persons. Some deaths temporally proximate to their use have occurred. There is speculation that these devices can cause dangerous cardiac rhythms. Swine research supports this hypothesis and has reported significant tachyarrhythmias. It is not known if this occurs in humans. The objective of this...

متن کامل

TASER X26 discharges in swine produce potentially fatal ventricular arrhythmias.

OBJECTIVES Data from the authors and others suggest that TASER X26 stun devices can acutely alter cardiac function in swine. The authors hypothesized that TASER discharges degrade cardiac performance through a mechanism not involving concurrent acidosis. METHODS Using an Institutional Animal Care and Use Committee (IACUC)-approved protocol, Yorkshire pigs (25-71 kg) were anesthetized, paralyz...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of Electromagnetic Analysis and Applications

سال: 2012

ISSN: 1942-0730,1942-0749

DOI: 10.4236/jemaa.2012.42012