Risk of exsanguination from a faulty arterial pressure transducer

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A new optical transducer for arterial pressure measurement.

A new optical pressure transducer system (Viggo) has been assessed and compared with a standard P10 transducer (Spectramed) using a similar 20-gauge cannula, both in vitro in terms of linearity and frequency response and in vivo using an animal model. The linearity of the transducers was comparable; the resonant frequencies were 106 Hz and 75 Hz, respectively. However, the resonant frequency of...

متن کامل

Factors Determining Systemic Arterial Pressure Causes of Hypotension Leading to " Shock " Example Classification Exsanguination

AN INVITATION to formulate definitions and a classification of shock for an international symposium' served as the impetus that led to a theoretical and experimental analysis of this subject. This initial experience with the field of shock research led us to the conclusion that clarification of semantic confusion is of prime importance for future progress in this area. "Shock" is employed to de...

متن کامل

Diagnosis of Different Causes of Arterial Blood Pressure by Arterial Catheter and Kidney Vein - A Case Report

1. Nous pouvons trouve une correlation precise entre les dosage de la renine et les aspects angiographiques uniquement dans les cas d'hypertension arterielle nephro­vasculaire·. 2. Cette correlation est importante pour deci. <l_er d'une="" intervention="" chirurgicale="" surtout="" en="" cas="" de="" lesion="" monolaterales,qui="" datent="" peu="" temps="" et="" qui="" ont="" valeurs="" ren...

متن کامل

Subnanowatt Microbubble Pressure Transducer

We present the first all-Parylene microbubble pressure transducer (μBPT). The μBPT utilizes an electrolytically generated microbubble (μB), trapped in a Parylene microchamber, for pressure sensing. Pressure-induced bubble size variation is detected by electrochemical impedance measurement. Real-time hydrostatic pressure measurement with excellent sensitivity (-10.7 Ω/psi, ±0.1 psi) up to 1.8 ps...

متن کامل

Effect of Islamic fasting on mean arterial pressure

Introduction: World Health Organization (WHO) introduced hypertension as an epidemic in developing countries. However, hypertension is adequately controlled in only 12.5% of patients.  The aim of this study was to evaluate the relationship between Ramadan fasting and mean arterial pressure (MAP). Methods: This clinical, observational study was carried out at Medical O.P.D of Jinnah Medical Coll...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Anaesthesia

سال: 2016

ISSN: 0003-2409

DOI: 10.1111/anae.13638