Risk of exsanguination from a faulty arterial pressure transducer
نویسندگان
چکیده
منابع مشابه
A new optical transducer for arterial pressure measurement.
A new optical pressure transducer system (Viggo) has been assessed and compared with a standard P10 transducer (Spectramed) using a similar 20-gauge cannula, both in vitro in terms of linearity and frequency response and in vivo using an animal model. The linearity of the transducers was comparable; the resonant frequencies were 106 Hz and 75 Hz, respectively. However, the resonant frequency of...
متن کاملFactors Determining Systemic Arterial Pressure Causes of Hypotension Leading to " Shock " Example Classification Exsanguination
AN INVITATION to formulate definitions and a classification of shock for an international symposium' served as the impetus that led to a theoretical and experimental analysis of this subject. This initial experience with the field of shock research led us to the conclusion that clarification of semantic confusion is of prime importance for future progress in this area. "Shock" is employed to de...
متن کاملDiagnosis of Different Causes of Arterial Blood Pressure by Arterial Catheter and Kidney Vein - A Case Report
1. Nous pouvons trouve une correlation precise entre les dosage de la renine et les aspects angiographiques uniquement dans les cas d'hypertension arterielle nephrovasculaire·. 2. Cette correlation est importante pour deci. <l_er d'une="" intervention="" chirurgicale="" surtout="" en="" cas="" de="" lesion="" monolaterales,qui="" datent="" peu="" temps="" et="" qui="" ont="" valeurs="" ren...
متن کاملSubnanowatt Microbubble Pressure Transducer
We present the first all-Parylene microbubble pressure transducer (μBPT). The μBPT utilizes an electrolytically generated microbubble (μB), trapped in a Parylene microchamber, for pressure sensing. Pressure-induced bubble size variation is detected by electrochemical impedance measurement. Real-time hydrostatic pressure measurement with excellent sensitivity (-10.7 Ω/psi, ±0.1 psi) up to 1.8 ps...
متن کاملEffect of Islamic fasting on mean arterial pressure
Introduction: World Health Organization (WHO) introduced hypertension as an epidemic in developing countries. However, hypertension is adequately controlled in only 12.5% of patients. The aim of this study was to evaluate the relationship between Ramadan fasting and mean arterial pressure (MAP). Methods: This clinical, observational study was carried out at Medical O.P.D of Jinnah Medical Coll...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Anaesthesia
سال: 2016
ISSN: 0003-2409
DOI: 10.1111/anae.13638