RF ablation thermal simulation model: Parameter sensitivity analysis
نویسندگان
چکیده
منابع مشابه
Considerations for Thermal Injury Analysis for RF Ablation Devices
BACKGROUND The estimation of lesion size is an integral part of treatment planning for the clinical applications of radiofrequency ablation. However, to date, studies have not directly evaluated the impact of different computational estimation techniques for predicting lesion size. In this study, we focus on three common methods used for predicting tissue injury: (1) iso-temperature contours, (...
متن کاملConstructing Verifiable Models for Rf Ablation Simulation
Modeling the process of radiofrequency ablation (RFA) to support pre-interventional prediction of the treatment result has been desired for more than one decade by now. Still a correct description is mathematically demanding and needs further investigation into medical facts. The process is highly dependent on the patient specific anatomy and physiology. Descriptions from an engineering perspec...
متن کاملS-Parameter Simulation of RF-HEMTs
This paper describes the results of a physically based time efficient method of simulating Sparameters of RF-High Electron Mobility Transistors (HEMTs) . In a frequency range from 2 GHz up to 120 GHz the simulated S-parameters show good agreement with the measurements obtained in the same frequency range. Using the two-dimensional device simulator MINIMOS-NT and a time domain method critical HE...
متن کاملSensitivity Analysis of MPSIAC Model
MPSIAC is currently known as an appropriate method to measure sediment ofWatershed basins of the country while there has not been any sensitivity analysis so far forthis method. In this study, required data for MPSIAC model were gathered from six basins;Amame-Kamarkhani, Kand-Golandok, Tang Kenesht (from two different references), Nojian(from three different references), Pegahe sorkh katvand (f...
متن کاملMonte Carlo simulation-based sensitivity analysis of the model of a thermal-hydraulic passive system
Thermal–Hydraulic (T–H) passive safety systems are potentially more reliable than active systems, and for this reason are expected to improve the safety of nuclear power plants. However, uncertainties are present in the operation and modeling of a T–H passive system and the system may find itself unable to accomplish its function. For the analysis of the system functional failures, a mechanisti...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Technology and Health Care
سال: 2018
ISSN: 0928-7329,1878-7401
DOI: 10.3233/thc-174542