Revisiting fetal dose during radiation therapy: evaluating treatment techniques and a custom shield [JACMP, 17(5), 2016]
نویسندگان
چکیده
منابع مشابه
Revisiting fetal dose during radiation therapy: evaluating treatment techniques and a custom shield [JACMP, 17(5), 2016]
This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited. © 2017 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine. TAB L E 7 The estimated fetal dos...
متن کاملRevisiting fetal dose during radiation therapy: evaluating treatment techniques and a custom shield
To create a comprehensive dataset of peripheral dose (PD) measurements from a new generation of linear accelerators with and without the presence of a newly designed fetal shield, PD measurements were performed to evaluate the effects of depth, field size, distance from the field edge, collimator angle, and beam modi-fiers for common treatment protocols and modalities. A custom fetal lead shiel...
متن کاملDesigning a shield to reduce radiation dose during mammography: Dosimetric evaluation
Background: This paper presents a method to reduce radiation exposure during mammography by analysing the doses to ipsilateral and contralateral breasts and to adjacent organs by evaluating material-dependent shielding performance. Materials and Methods: Six target-filter combinations (Mo-Mo, Mo-Rh, Rh-Rh, Rh-Mo, W-Mo, W-Rh) were tested by measuring the doses delivered to the breasts and adjac...
متن کاملDesign of a generally applicable abdominal shield for reducing fetal dose during radiotherapy of common malignancies in pregnant patients
Background: In most cancer cases, the treatment choice for a pregnant patient is radiotherapy. In these patients, the abdomen is usually not exposed therefore fetus exposure is due to peripheral dose (PD). The purpose of this study was to estimate the fetal dose (the maximum PD in each pregnancy stage) for modalities available and to fabricate and evaluate a generally applicable fetal ...
متن کاملAnalysis of Hip Joint Dose in Prostate Cancer Radiation Therapy: A Dosimetric Comparison of Treatment Plans
Background and purpose: Radiation therapy as a part of cancer treatment is used in almost 50-60% of involved cases. In prostate cancer radiation therapy, a large volume of pelvis is irradiated, so, it is necessary to preserve sensitive organs around the treatment area, especially rectum and bladder. In this study, some dosimetric parameters such as minimum dose (Dmin), maximum dose (Dmax), mean...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Applied Clinical Medical Physics
سال: 2017
ISSN: 1526-9914
DOI: 10.1002/acm2.12191