منابع مشابه
Revision of failed total hip arthroplasty.
Ninety-seven revisions of total hip replacements are reviewed with a median time of observation of 47 months. Satisfactory pain relief was obtained in 86%. There were six complete failures which were reduced to three by further surgery. One hip became infected and was excised. In 12 cases the revisions were complicated by peroperative fractures and in five by dislocations. Radiographic analysis...
متن کاملFemoral Component Revision of Total Hip Arthroplasty.
Modern primary total hip arthroplasty (THA) is among the most successful operations in medicine. It has been a consistently effective treatment for end-stage osteoarthritis of the hip. With the increasing number of primary THA procedures being performed and the decreasing age of patients undergoing the procedure, there is an inevitable associated increase in revision burden for arthroplasty sur...
متن کاملRevision Total Hip Arthroplasty for Aseptic Failure
The results of 276 cemented revision total hip arthroplasties performed for aseptic failure between 1977 and 1986 have been reviewed. The mean time between revision and review was 75 months (range 30 to 144). Of 220 cases available for review, 159 were assessed clinically and radiographically, and 32 by postal questionnaire. Eighteen hips required further revision, 12 for loosening, two for sep...
متن کاملRevision total hip arthroplasty in Jehovah's Witnesses.
Revision total hip arthroplasty (THA) is associated with greater blood loss than primary THA. Jehovah's Witnesses will not accept transfusions of blood or blood products and are thus at an increased risk for complications due to perioperative anemia. The purpose of this study was to report the clinical outcomes, radiographic outcomes, morbidity, and mortality of Jehovah's Witnesses who were med...
متن کاملImpaction Grafting for Revision Total Hip Arthroplasty
Impaction grafting for revision total hip arthroplasty is increasingly being used in cases complicated by substantial bone loss. Many techniques using cemented and noncemented designs with or without bone graft have had unpredictable outcomes and are the source of continuing debate. This new technique uses morselized allograft, impacted into a constrained femoral envelope, creating a new medull...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Orthopedics & Traumatology
سال: 1987
ISSN: 1349-4333,0037-1033
DOI: 10.5035/nishiseisai.36.545