Revision of Total Hip Arthroplasty Using Allograft.
نویسندگان
چکیده
منابع مشابه
Revision total hip arthroplasty using an interlocking stem with an allograft-prosthesis composite.
We report the clinical and radiographic outcomes and complications of revision surgery using a cementless interlocking stem with an allograft-prosthesis composite (APC). This study included 11 patients with an average follow-up of 73 years. Of the 11 revisions, 1 was aseptic, 7 were septic, and 3 were periprosthetic femoral fractures. The mean Harris hip score improved from 25.6 points before s...
متن کاملRevision of failed total hip arthroplasty.
Ninety-seven revisions of total hip replacements are reviewed with a median time of observation of 47 months. Satisfactory pain relief was obtained in 86%. There were six complete failures which were reduced to three by further surgery. One hip became infected and was excised. In 12 cases the revisions were complicated by peroperative fractures and in five by dislocations. Radiographic analysis...
متن کاملFemoral Component Revision of Total Hip Arthroplasty.
Modern primary total hip arthroplasty (THA) is among the most successful operations in medicine. It has been a consistently effective treatment for end-stage osteoarthritis of the hip. With the increasing number of primary THA procedures being performed and the decreasing age of patients undergoing the procedure, there is an inevitable associated increase in revision burden for arthroplasty sur...
متن کاملTotal femoral allograft with simultaneous revision total hip and knee arthroplasty: 18 year follow-up
Massive allograft can be a useful option in revision total joint arthroplasty for treatment of significant bone loss. In rare cases, revision hip and knee arthroplasty procedures can be performed simultaneously using massive allograft-prosthetic composites. We present an 18 year follow up of a patient who received a simultaneous revision hip and knee total femoral allograft and discuss recent l...
متن کاملRevision Total Hip Arthroplasty for Aseptic Failure
The results of 276 cemented revision total hip arthroplasties performed for aseptic failure between 1977 and 1986 have been reviewed. The mean time between revision and review was 75 months (range 30 to 144). Of 220 cases available for review, 159 were assessed clinically and radiographically, and 32 by postal questionnaire. Eighteen hips required further revision, 12 for loosening, two for sep...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Orthopedics & Traumatology
سال: 2000
ISSN: 1349-4333,0037-1033
DOI: 10.5035/nishiseisai.49.1177