REVISION ACETABULAR CUP REPLACEMENT WITH BURCH - SCHNEIDER CAGE: OUR EXPERIENCE
نویسندگان
چکیده
منابع مشابه
Burch-Schneider cage fracture: a case report.
In this report, we present the case of a 64-year-old woman who sustained a Burch-Schneider cage fracture. Prior to this event, she underwent repeated acetabular reconstructions, but in the end prosthesis removal was performed as a salvage procedure. We believe that the primary cause of the fracture was metal fatigue facilitated by intraoperative re-contouring of the flange, as well as reuse of ...
متن کاملAcetabular Cup Revision
The use of acetabular cup revision arthroplasty is on the rise as demands for total hip arthroplasty, improved life expectancies, and the need for individual activity increase. For an acetabular cup revision to be successful, the cup should gain stable fixation within the remaining supportive bone of the acetabulum. Since the patient's remaining supportive acetabular bone stock plays an importa...
متن کاملAcetabular Reconstruction with the Burch-Schneider Antiprotrusio Cage and Bulk Allografts: Minimum 10-Year Follow-Up Results
Reconstruction of severe pelvic bone loss is a challenging problem in hip revision surgery. Between January 1992 and December 2000, 97 hips with periprosthetic osteolysis underwent acetabular revision using bulk allografts and the Burch-Schneider antiprotrusio cage (APC). Twenty-nine patients (32 implants) died for unrelated causes without additional surgery. Sixty-five hips were available for ...
متن کاملAcetabular revision in total hip replacement with a press-fit cup.
The need for supplementary screw fixation in acetabular revisions is still widely debated. We carried out 439 acetabular revisions over an eight-year period. In 171 hips with contained or small segmental defects, the Morscher press-fit cup was used. These revisions were followed prospectively. No screws were used for additional fixation. A total of 123 hips with a mean follow-up of 7.4 years (5...
متن کاملNavigated Acetabular Cup Fixation for Acetabular Deformity or Revision Total Hip Arthroplasty
PURPOSE To evaluate the usefulness of navigated acetabular cup fixation for total hip arthroplasty in patients with acetabular deformity or revision total hip arthroplasty. MATERIALS AND METHODS This study enrolled 28 patients with at least 12 months' follow-up. The safe zone of the acetabular cup was defined as 40°±10°in inclination and 15°±10°in anteversion. The authors used the navigation ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Evolution of Medical and Dental Sciences
سال: 2015
ISSN: 2278-4748,2278-4802
DOI: 10.14260/jemds/2015/1793