Review on research of water saving for natural ventilation cooling tower
نویسندگان
چکیده
Thermal power plant is one of the eight high water consumption industries in China, and circulating cooling largest project. Under increasingly severe situation resources measures must be taken to reduce evaporation loss, wind blowing loss pollution discharge natural ventilation tower. Based on comprehensive summary water-saving technology tower, we compared advantages disadvantages various technologies provide a basis for transformation
منابع مشابه
Study of Degradation of Dry Cooling Tower Performance under Wind Conditions and Method for Tower Efficiency Enhancement (RESEARCH NOTE)
Wind affects adversely the cooling tower thermal performance. A field investigation was carried out to study the thermal performance of Heller cooling towers under wind conditions, involving measurement of wind velocity and its direction around the cooling tower, and obtaining water flow rates and temperatures at the cooling tower inlet and outlet. Results show that air suction at the tower top...
متن کاملExperimental and numerical study of natural ventilation in four-sided wind tower traps
In the past, wind towers were applied as the main architectural part of building construction in the desert areas of Iran. These almost high structures were used as cooling load suppliers at residential buildings. In the present study, the effect of symmetric four-sided wind tower in flow induction to the bottom space has been analysed by using a wind tunnel and numerical simulations. In the nu...
متن کاملOptimization of Water - Cooled Chiller – Cooling Tower Combinations
Water-cooled chiller systems have typically been designed around entering condenser water temperatures of 85°F with a Optimization of Water Cooled Chiller – Cooling Tower Combinations The warm water leaving the chilled water coils is pumped to the evaporator of the chiller, where the unwanted heat from the building is transferred by the latent heat of vaporization of the refrigerant. The compre...
متن کاملFactors stimulating propagation of legionellae in cooling tower water.
Our survey of cooling tower water demonstrated that the highest density of legionellae, >/=10 CFU/100 ml, appeared in water containing protozoa, >/=10 MPN/100 ml, and heterotrophic bacteria, >/=10 CFU/100 ml, at water temperatures between 25 and 35 degrees C. Viable counts of legionellae were detected even in the winter samples, and propagation, up to 10 CFU/100 ml, occurs in summer. The counts...
متن کاملNumerical and Analytical Study of Natural Dry Cooling Tower in a Steam Power Plant
Design of a natural dry cooling tower has been accomplished in two sections: the design of heat exchangers and the numerical solution of flow through the tower. Heat exchanger (Heller type) has been simulated thermodynamically and then coupled with a computer program, which calculated the turbulent natural convection flow through the tower. The computer program developed for this purpose can be...