Review of signal distortion through metal microelectrode recording circuits and filters
نویسندگان
چکیده
منابع مشابه
Review of signal distortion through metal microelectrode recording circuits and filters.
Interest in local field potentials (LFPs) and action potential shape has increased markedly. The present work describes distortions of these signals that occur for two reasons. First, the microelectrode recording circuit operates as a voltage divider producing frequency-dependent attenuation and phase shifts when electrode impedance is not negligible relative to amplifier input impedance. Becau...
متن کاملAdvances in Microelectrode and Multielectrode Recording Techniques
www.ephysinnovation.com Electrophysiology Innovation Partnership e.V. Markwiesenstr. 55 72770 Reutlingen, Germany [email protected] Workshop Coordinators: H. R. Polder, npi electronic GmbH, [email protected] I. Herzberg, ALA Scientific Instruments [email protected] Pharmacology of two nicotinic acetylcholine receptor subtypes on insect CNS neurons studied with the Single-Electr...
متن کاملCharacterization and optimization of microelectrode arrays for in vivo nerve signal recording and stimulation.
Revealing the complex signal-processing mechanisms and interconnection patterns of the nervous system has long been an intriguing puzzle. As a contribution to its understanding the optimization of the impedance behavior of implantable electrode arrays with via holes is discussed here. Peripheral axons will regenerate through these holes allowing for simultaneous nerve stimulation and signal rec...
متن کاملDesign and Fabrication of A High Density Metal Microelectrode Array for Neural Recording
We report a new fabrication technique for realizing a high-density penetrating metal microelectrode array intended for acute multipleunit neural recordings. The microelectrode array consists of multiple metal (Permalloy, Ni80Fe20) shanks projecting from a silicon supporting bulk. Neuron recording sites are located at the tip of each shank. The average distance between recording sites is 50 μm. ...
متن کاملMicrofabrication and Characterisation of Microelectrode Arrays for in Vivo Nerve Signal Recording
The present work was performed in the framework of the ESPRIT-project "INTER" aimed at the development of an "intelligent" artificial interface between the living nerve system and electronic devices. The design, the fabrication, and the characterisation of regeneration-type microelectrode arrays for in vivo recording of nerve signals is described here. The impedance of the microelectrodes could...