Review of Magnetorheological Damping Systems on a Seismic Building

نویسندگان

چکیده

Building structures are vulnerable to the shocks caused by earthquakes. Buildings that have been destroyed an earthquake very detrimental in terms of material loss and mental trauma. However, technological developments now enable us anticipate from earthquakes minimize losses. One technologies has used, is currently being further developed, a damping device fitted building structure. There various types devices, each with different characteristics systems. Multiple studies on devices resulted development types, such as friction dampers (FDs), tuned mass (TMDs), viscous (VDs). attenuation mostly based type system can be divided into three categories, namely passive, active, semi-active. As such, their own advantages disadvantages. This study investigated efficacy magnetorheological (MR) damper, viscous-type semi-active system, simulation applied damper side Although MR extensively used developed inter-story few analyzed models controls even though both equally important controlled for Of models, Bingham model most popular indicated large number publications available subject. Most adapt because it straightforward all models. Fuzzy often simulations experiments. review provides benefits investigation especially use fluids working fluids. In particular, this paper fundamental modeling control systems buildings. fact, no less attractive than other dampers. Their reliability related control, which could turned interesting discussion investigation.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Seismic Mitigation of Building Frames using Magnetorheological Damper (TECHNICAL NOTE)

The present study focusses on the damping force control of shear mode magnetorheological (MR) damper for seismic mitigations. Therefore, the semi-active MR damper which can control the vibration is analyzed both experimentally and numerically. Carbonyl iron is used as the magnetic particle and Castrol Magnetec oil as carrier fluid throughout the study. MR damper is designed and fabricated, and ...

متن کامل

the impact of peer review on efl reviewers writing proficiency

امروزه تصحیح همکلاسی در کلاسهای نگارش یکی از اجزاء لاینفک کلاسهای دانش آموز محور است. تاثیرات مفید تصحیح همکلاسی بر زبان آموزان، معلمان را متقاعد کرده است که علیرغم صرف زمان، انرژی و توان بسیار، از این شیوه ی آموزشی در کلاسهای آموزش نگارش بهره بگیرند. تحقیق حاضر بر آن است تا با مقایسه دو گروه از یادگیرندگان زبان انگلیسی، تاثیر تصحیح همکلاسی را بر توانایی نوشتاری آنها نشان دهد. 122 خانم زبان آمو...

15 صفحه اول

Seismic Responses of Civil Structures under Magnetorheological-device Direct Control

This paper presents an efficient control strategy for magnetorheological (MR) dampers embedded in building structures to mitigate quake-induced vibrations. In this work, MR dampers are used as semi-active devices, taking the advantages of the fail-safe operation and low power requirement. By using a static hysteresis model for the MR damper, a suitable controller is proposed here for direct con...

متن کامل

Modeling and Control of Magnetorheological Dampers for Seismic Response Reduction

Control of civil engineering structures for earthquake hazard mitigation represents a relatively new area of research that is growing rapidly. Control systems for these structures have unique requirements and constraints. For example, during a severe seismic event, the external power to a structure may be severed, rendering control schemes relying on large external power supplies ineffective. M...

متن کامل

damping of stay cable with passive-on magnetorheological dampers: a full-scale test

damping of a full-scale cable with a pair of passive–on magnetorheological (mr) dampers was tested. a cable of 215.58m long with the first mode frequency of 0.658hz was tensioned horizontally in cable prefabrication factory. two mr dampers were attached to the cable in an angle in the plane perpendicularly to the cable axis in 5m length from the cable anchorage. the applied voltage level was 0v...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Applied sciences

سال: 2021

ISSN: ['2076-3417']

DOI: https://doi.org/10.3390/app11199339