Retrograde Renal Arteriography Using a Balloon-fitted Vascular Catheter
نویسندگان
چکیده
منابع مشابه
Intraoperative Tracking of Anatomical Structures Using Fluoroscopy and a Vascular Balloon Catheter
We present preliminary work on a novel technique for tracking anatomical structures during medical procedures. A vascular balloon catheter is placed within a vessel in the structure of interest and is inflated using a radioopaque contrast material. The balloon catheter is tracked over time using a fluoroscopy system, and three parameters of motion are determined (two of translation, one of rota...
متن کاملCryo-balloon catheter position planning using AFiT
Atrial fibrillation (AFib) is the most common heart arrhythmia. In certain situations, it can result in life-threatening complications such as stroke and heart failure. For paroxsysmal AFib, pulmonary vein isolation (PVI) by catheter ablation is the recommended choice of treatment if drug therapy fails. During minimally invasive procedures, electrically active tissue around the pulmonary veins ...
متن کاملEndoscopic retrograde cholangiography of a hepaticojejunostomy using double balloon enteroscopy.
Examination of a biliodigestive anastomosis presents a diagnostic and therapeutic challenge. Visualization of biliodigestive anastomosis and endoscopic retrograde cholangiography with intervention is possible with a double balloon enteroscope.
متن کاملCoronary Arteriography by the Single Catheter
A new percutaneous femoral method for studying the coronary arteries, left ventricle and saphenous vein bypass grafts using a single catheter has been developed. A #8 French 100 cm polyurethane catheter with wire incorporated and a 450 curved tip has been used in 6,800 patients. This technique combines the speed and simplicity of the percutaneous femoral approach with the safety of the single c...
متن کاملLocal antithrombotic therapy using a novel porous balloon catheter.
The efficacy of local treatment of thrombosis with low-dose antithrombotic drugs (heparin: 30 U/kg, or argatroban: 0.02 mg/kg) was investigated using a novel porous balloon catheter. This novel balloon catheter can deliver drug into arterial walls without causing vascular trauma. Thrombus formation was significantly inhibited in balloon-injured and locally-treated iliac arteries compared with c...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: The Tohoku Journal of Experimental Medicine
سال: 1965
ISSN: 0040-8727,1349-3329
DOI: 10.1620/tjem.85.378