Retrofitting Apartment Buildings To Reduce Costs and Water Demand
نویسندگان
چکیده
منابع مشابه
Retrofitting Listed Buildings: Measures, Savings and Requirements
The paper presents a case study where the energy demand for a listed building constructed in 1900 is reduced. Many older buildings are listed and have restrictions that include the entire building or that include only its exterior. For the building presented, only its exterior facade is listed. The paper demonstrates measures for the improvement of the thermal insulation of the building with so...
متن کاملIntroduction of Air Cushion to Reduce Seismic Demand in Cylindrical Water Storage Tanks
Water storage tanks not designed explicitly for seismic loading could require retrofit. One of the common ways of retrofit include some structural change in the lateral load resisting system that could be expensive and requires the tank to be out of service for relatively long time. This paper introduces a novel method to reduce seismic demand on tank’s wall without structural intervention. Thi...
متن کاملPredictive control methods to improve energy efficiency and reduce demand in buildings
This paper presents an overview of results and future challenges on temperature control and cost optimization in building energy systems. Control and economic optimization issues are discussed and illustrated through sophisticated simulation examples. The paper concludes with effective results from model predictive control solutions and identification of important directions for future work.
متن کاملEnergy savings and economics of retrofitting single-family buildings
This s tudy a s se s se s the energy savings and cost-effect iveness of individual retrofi t op t ions and packages of measu res in s ingle-family buildings, ba sed on analysis of me te red energy consumpt ion and actual installation costs. We present results for 14 individual shell, heating system, and water heating measures, as well as 21 electric utility weatherization programs. The data on ...
متن کاملFormulation of design eccentricity to reduce ductility demand in asymmetric buildings
A critical analysis of the large number of papers about the seismic behaviour of asymmetric buildings shows some concordant results: the modal analysis correctly predicts their elastic dynamic response to seismic records, while it overestimates deck rotation in the inelastic range. On this basis, the authors propose to design asymmetric structures by twice repeating the modal analysis: the firs...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Canadian Water Resources Journal
سال: 1984
ISSN: 0701-1784,1918-1817
DOI: 10.4296/cwrj0903045