Retrievable Filter Update: The Denali Vena Cava Filter

نویسندگان

چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Inferior vena cava filter thrombosis

Patients with inferior vena cava (IVC) filters - particularly permanent filters - are at increased risk for recurrent deep venous thrombosis (DVT). Judicious use of IVC filters, as well as the prompt retrieval of temporary IVC filters, substantially reduces the risk of IVC thrombosis.

متن کامل

Perforation of Inferior Vena Cava by Inferior Vena Cava Filter

Supervising Section Editor: Sean O. Henderson, MD Submission history: Submitted June 13, 2012; Accepted August 6, 2012 Full text available through open access at http://escholarship.org/uc/uciem_westjem DOI: 10.5811/westjem.2012.8.12795 [West J Emerg Med 2013;14(2):161-162.] Sarah Unterman, MD* Tad Nair, MD† Jesse Brown VA Medical Center, Department of Emergency Medicine, Chicago, Illinois Univ...

متن کامل

The Celect Platinum Inferior Vena Cava Filter

T he concept of surgical caval interruption was suggested as early as 1868 by Trousseau, who proposed creating a barrier in the inferior vena cava (IVC) to prevent venous emboli from the legs from reaching the lungs.1 In 1967, nearly 100 years later, the first endovenous filter was implanted.2 Although the basic concept of caval filtration has largely remained the same over the past century, ad...

متن کامل

Wire in the Heart: Fracture and Fragment Embolization of Retrievable Inferior Vena Cava Filter into the Right Ventricle

We report a case of a 58-year-old female who was found to have a fractured limb of her IVC filter in her right ventricle during a cardiac catheterization. A 25 mm radioopaque thin linear structure was seen in the proximal portion of the right ventricle. It was fixed and did not migrate or change position during investigations. On fluoroscopy, the IVC filter was observed in an appropriate locati...

متن کامل

The safety and effectiveness of the retrievable option inferior vena cava filter: a United States prospective multicenter clinical study.

PURPOSE To evaluate the safety and effectiveness of the retrievable Option inferior vena cava (IVC) filter in patients at risk for pulmonary embolism (PE). MATERIALS AND METHODS This was a prospective, multicenter, single-arm clinical trial. Subjects (N = 100) underwent implantation of the IVC filter and were followed for 180 days; subjects whose filters were later removed were followed for 3...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Seminars in Interventional Radiology

سال: 2015

ISSN: 0739-9529,1098-8963

DOI: 10.1055/s-0035-1564812