Results from a Prototype Proton-CT Head Scanner
نویسندگان
چکیده
منابع مشابه
Results from a Pre - Clinical Head Scanner
We report on the first beam test results with our pre-clinical (Phase-II) head scanner developed for proton computed tomography (pCT). After extensive preclinical testing, pCT will be employed in support of proton therapy treatment planning and pre-treatment verification in patients undergoing treatment with particle beam therapy. The Phase-II pCT system consists of two silicon-strip telescopes...
متن کاملWater-equivalent path length calibration of a prototype proton CT scanner.
PURPOSE The authors present a calibration method for a prototype proton computed tomography (pCT) scanner. The accuracy of these measurements depends upon careful calibration of the energy detector used to measure the residual energy of the protons that passed through the object. METHODS A prototype pCT scanner with a cesium iodide (CsI(Tl)) crystal calorimeter was calibrated by measuring the...
متن کاملVolumetric perfusion CT using prototype 256-detector row CT scanner: preliminary study with healthy porcine model.
This is a preliminary demonstration of volumetric perfusion CT of the brain in domestic pigs by using a prototype 256-detector row CT. Scan range is approximately 100 mm in the craniocaudal direction with 0.5-mm section thickness. The 256-detector row CT is an easily available imaging technique that can provide volumetric cine imaging, CT angiography, and perfusion CT in a wide craniocaudal cov...
متن کاملReview of portable CT with assessment of a dedicated head CT scanner.
This article reviews a number of portable CT scanners for clinical imaging. These include the CereTom, Tomoscan, xCAT ENT, and OTOscan. The Tomoscan scanner consists of a gantry with multisection detectors and a detachable table. It can perform a full-body scanning, or the gantry can be used without the table to scan the head. The xCAT ENT is a conebeam CT scanner that is intended for intraoper...
متن کاملExperimental results from a preclinical X-ray phase-contrast CT scanner.
To explore the future clinical potential of improved soft-tissue visibility with grating-based X-ray phase contrast (PC), we have developed a first preclinical computed tomography (CT) scanner featuring a rotating gantry. The main challenge in the transition from previous bench-top systems to a preclinical scanner are phase artifacts that are caused by minimal changes in the grating alignment d...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Physics Procedia
سال: 2017
ISSN: 1875-3892
DOI: 10.1016/j.phpro.2017.09.060