Restricted Earth Fault Protection in Low-Impedance Grounded Systems With Inverter-Based Resources

نویسندگان

چکیده

A restricted earth fault (REF) protection element provides sensitive detection of ground faults near the neutral a transformer or generator. The sensitivity gains from REF are especially more valuable when equipment is low-impedance grounded phase differential (87T) ineffective. However, faces several challenges in systems, which becoming prevalent inverter-based resource (IBR) plants. Dependability may be compromised if zero-sequence current at terminal capacitive for an internal fault. Security jeopardized external faults, such as phase-to-phase-to-ground evolving with (CT) saturation. Using field events IBR plants and simulations, this paper discusses design improvements to systems. CT selection criteria setting guidance reliable operation provided. Finally, coverage provided by compared 87T highlight its benefits

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A New Restricted Earth Fault Relay Based on Artificial Intelligence

The restricted earth fault (REF) relay is a type of differential protection which is used for detection of internal ground faults of power transformers. But, during external faults and transformer energization conditions, the probability of current transformer (CT) saturation increases. Thus, the spurious differential current due to CT saturation, can lead to REF relay maloperation. In this pap...

متن کامل

A Novel Solution to Restricted Earth Fault Low Impedance Relay Maloperation

In this paper, various methods of providing restricted earth fault protection are discussed. The proper operation of high and low impedance Restricted Earth Fault (REF) protection for various applications has been discussed. The maloperation of a relay due to improper placement of CTs has been identified and a simple/unique solution has been proposed in this work with a case study. Moreover, it...

متن کامل

Effect of TCSR on Measured Impedance by Distance Protection in Presence Single Phase to Earth Fault

This paper presents the impact study of apparent reactance injected by series Flexible AC Transmission System (FACTS) i.e. Thyristor Controlled Series Reactor (TCSR) on the measured impedance of a 400 kV single electrical transmission line in the presence of phase to earth fault with fault resistance. The study deals with an electrical transmission line of Eastern Algerian transmission networks...

متن کامل

Review of Ground Fault Protection Methods for Grounded, Ungrounded, and Compensated Distribution Systems

This paper reviews ground fault protection and detection methods for distribution systems. First, we review and compare medium-voltage distribution-system grounding methods. Next, we describe directional elements suitable to provide ground fault protection in solidlyand lowimpedance grounded distribution systems. We then analyze the behavior of ungrounded systems under ground fault conditions a...

متن کامل

Impedance-based Structural Health Monitoring of Thermal Protection Systems

Components used for thermal protection have not previously been interrogated with the impedance method. In this study, structures are fabricated to represent typical thermal protections systems. The replicas are designed to simulate actual protection systems in use. Observations are made into the verification of the impedance method in effectively monitoring complex thermal protection systems f...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: IEEE Transactions on Power Delivery

سال: 2023

ISSN: ['1937-4208', '0885-8977']

DOI: https://doi.org/10.1109/tpwrd.2022.3195741