Response Surface Method for the Simultaneous Estimation of Atorvastatin and Olmesartan

نویسندگان

چکیده

The simultaneous estimation of Atorvastatin Calcium (ATS) and Olmesartan Medoxomil (OLM) in bulk pharmaceutical dosage forms, a new, quick, cost-effective Reverse Phase High Performance Liquid Chromatography (RP-HPLC) method has been developed. experimental design was used to achieve multivariate optimization the RP-HPLC conditions. Three independent variables were create mathematical models: Acetonitrile content mobile phase composition, buffer pH, flow rate. Here, applied model central composite (CCD) research response surface methodology study effects factors. Shimadzu (LC 20 AT VP) HPLC system with Spinchrom software used. Zodiac, C18 (250×4.6 ID) 5μm column, phosphate buffers, acetonitrile as ratio 40:60 v/v rate 1.15 mL/min. eluent monitored at 212 nm using Prominence UV-Visible detector. retention time for OLM ATS 2.673 3.717, respectively. optimized procedure validated per ICH guidelines. correlation coefficient 0.9869 0.9832. % recovery 98.59, 99.68 %. had LOD 17.568 μg/mL, while 12.88 μg/mL. LOQ 53.24 39.04 pH aqueous phase, solvent most stringent affecting responses, according 3D graphs. A new accurate precise approach developed regularly analyse ATS.
 HIGHLIGHTS
 
 forms
 by method
 Developed guidelines
 GRAPHICAL ABSTRACT

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Stability Indicating Rp-hplc Method for the Simultaneous Determination of Olmesartan Medoxomil and Atorvastatin Calcium

A simple, rapid, and precise, stability indicating RP-HPLC method for simultaneous analysis of olmesartan medoxomil (OLM) and Atorvastatin (ATR) in bulk has been developed and validated. The analytes were separated by using a Waters symmetry C18 analytical column (250mm × 4.6mm, 5 μm) with a mobile phase consisting of Acetonitrile and 0.02 M potassium dihydrogen phosphate buffer containing 0.1%...

متن کامل

Simultaneous Estimation of Metoprolol Succinate and Olmesartan

A simple, precise, specific and accurate reverse phase HPLC method has been developed for the simultaneous determination of Metoprolol succinate (METO) and Olmesartan medoxomil (OLME) in tablet dosage form. The chromatographic separation was achieved on inertsil ODS 3V (250 mm×4.6 mm, 5 μm) column using PDA detector. The mobile phase consisting of Buffer (2 ml O-phosphoric acid in 2000 ml milli...

متن کامل

preparation and characterization of new co-fe and fe-mn nano catalysts using resol phenolic resin and response surface methodology study for fischer-tropsch synthesis

کاتالیزورهای co-fe-resol/sio2و fe-mn-resol/sio2 با استفاده از روش ساده و ارزان قیمت همرسوبی تهیه شدند. از رزین پلیمری resol در فرآیند تهیه کاتالیزور استفاده شد.

HPLC method development and validation for simultaneous estimation of Olmesartan Medoxomil, Hydrochlorothiazide and Amlodipine Besylate tablets

In the present work for the determination of Olmesartan Medoxomil, Hydrochlorothiazide and Amlodipine a simple, rapid and precise high performance liquid chromatography procedure has been developed and validated. The separation and quantification were achieved on a Cyano C18 column using a mobile phase of filtered and degassed mixture of buffer and acetonitrile in the ratio of 830:170 with of a...

متن کامل

Application of Response Surface Method to the Estimation of Bond Work Index

Introduction The main objective of this contribution is to focus on the portion of the comminution process which deals with the prediction of the energy consumption due to the comminution portion of the milling processes. The comminution energy in mineral processing and cement industry is usually determined by empirical Bond Work Index (BWI), regardless of the mechanical properties of a rock....